Renke RS-ZS-BZ-*-T onboard sound sensor for real-time A-weighted noise measurement, designed to be embedded in devices or enclosures.
Frequency response range20Hz~12.5kHz
Measure range30dB~130dB(0~3V is 30dB~120dB)
Power consumption18.9mA@5V, 31.0mA@12V, 27.8mA@24V
Frequency weightingA weighting
Accuracy±0.5dB (at reference pitch, 94dB@1kHz)
Circuit working environment-20℃~+60℃, 0%RH~95%RH (non-condensing)
Product overview
Overview. The Renke RS-ZS-BZ-*-T is a PCB-mounted sound sensor designed for real-time A-weighted noise measurement over a range of 30 dB to 130 dB. It embeds into devices or enclosures thanks to a standard 2.54 mm pin header.
Main characteristics. The sensor uses a high-performance pre-polarized back electret condenser microphone combined with a filter foam. It offers two measurement modes, slow and fast, with response times of 500 ms in fast mode and 1.5 s in slow mode. Accuracy is ±0.5 dB at 94 dB@1 kHz, the frequency response spans 20 Hz to 12.5 kHz and stability is less than 2% during the period of use. The 0~3 V output corresponds to 30~120 dB. The dust cover effect is 0.5 dB or less in the range of 50~115 dB and 0.7 dB or less in the other ranges.
Interfaces and connectivity. Several outputs are available: UART (TTL) with an output voltage of 0~3.3 V and an input voltage of 0~3.3 V compatible with 5 V, RS-485 using the ModBus-RTU communication protocol, IIC, and 0~3 V analog output. UART or RS-485 communication uses 9600 N 8 1. The sensor can be connected to a PLC or a supervision system through the ModBus-RTU protocol.
Power and environment. The working voltage is 4.5~5.5 V by default, with a 10~28 V option. Power consumption is 18.9 mA@5 V, 31.0 mA@12 V and 27.8 mA@24 V. The circuit operates between -20 °C and +60 °C, from 0% to 95% RH non-condensing, and at a static pressure of 65 kPa to 106 kPa. It should be installed away from strong mechanical vibration, impact, strong electromagnetic fields and corrosive gases.
Typical uses. The sensor suits noise measurement in industrial sites, transportation, factories, construction projects and public spaces, using the A-weighting applied to environmental noise measurement.
Output voltage: 0~3.3V; Input voltage: 0~3.3V compatible with 5V
Power consumption
18.9mA@5V, 31.0mA@12V, 27.8mA@24V
Reference calibration point
94dB calibration, reference sound pressure level 20uPa, frequency 1kHz
Response time — Fast mode
500ms
Response time — Slow mode
1.5s
Stability
Less than 2% during the use period
UART or RS-485 communication
9600 N 8 1
Working Environment
Air temperature: -20~+60℃, static pressure: 65kPa~106kPa. There is no strong mechanical vibration, impact, strong electromagnetic field and corrosive gas around.
Working voltage
4.5~5.5V (default), 10~28V (optional)
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for SOUND-SENSOR. For a missing document or a specific revision, our experts send it to you.
Output voltage: 0~3.3V; Input voltage: 0~3.3V compatible with 5V
Power consumption
18.9mA@5V, 31.0mA@12V, 27.8mA@24V
Reference calibration point
94dB calibration, reference sound pressure level 20uPa, frequency 1kHz
Response time — Fast mode
500ms
Response time — Slow mode
1.5s
Stability
Less than 2% during the use period
UART or RS-485 communication
9600 N 8 1
Working Environment
Air temperature: -20~+60℃, static pressure: 65kPa~106kPa. There is no strong mechanical vibration, impact, strong electromagnetic field and corrosive gas around.
Working voltage
4.5~5.5V (default), 10~28V (optional)
Applications and use cases
Architectures in which SOUND-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for SOUND-SENSOR and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productRenke
SOUND-SENSOR
Onboard sound sensor with multiple outputs for PCB
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details