Wall-mounted sulfur dioxide (SO2) sensor with an electrochemical cell, designed for real-time monitoring of gas concentrations in an indoor area.
Measure range0-20ppm/0-2000ppm
Average power consumption0.18W
Accuracy±5%FS or ±10%
Response time20ppm:≤45s, 2000ppm:≤70s
ModelRS-SO2*-*-2-*-T
Output signalRS485/4-20mA/0-5V/0-10V
Product overview
Overview. The Renke RS-SO2*-*-2-*-T is a wall-mounted sulfur dioxide (SO2) sensor with an electrochemical cell, designed for real-time monitoring of this toxic gas concentration.
Main characteristics. Two measurement ranges are available, 0-20 ppm and 0-2000 ppm, with an accuracy of ±5% FS or ±10%, a repeatability of 2% or less and a stability of 2% of signal value or less per month. Resolution is 0.1 ppm on the 20 ppm range and 1 ppm on the 2000 ppm range. Response time is 45 s or less on 20 ppm and 70 s or less on 2000 ppm, with a warm-up time of at least 5 min.
Interfaces and connectivity. The sensor offers four selectable outputs: RS485, 4-20 mA, 0-5 V and 0-10 V. The RS485 output allows connection to a monitoring host for centralised collection of multi-point measurements.
Power and environment. It is powered from 10 to 30 V DC, has an average power consumption of 0.18 W and operates between -20 and 50 °C, at 15 to 90% RH non-condensing, under a pressure of 90 to 110 kPa.
Typical uses. This sensor suits sulfur dioxide leak detection and ambient monitoring in industrial installations, with an RS485 link compatible with PLCs.
Integration. The RS485 output and the 4-20 mA or 0-10 V analogue signals ease integration into an existing measurement chain. The housing is waterproof.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for SULFUR-DIOXIDE-SENSOR, with where it comes from. Use the filters to find one quickly.
All specifications (14)
Characteristic
Value
Response time
20ppm:≤45s, 2000ppm:≤70s
Accuracy
±5%FS or ±10%
Average power consumption
0.18W
Measure range
0-20ppm/0-2000ppm
Model
RS-SO2*-*-2-*-T
Output signal
RS485/4-20mA/0-5V/0-10V
Power supply
10~30V DC
Repeatability
≤2%
Resolution
20ppm:0.1ppm, 2000ppm:1ppm
Stability
≤2% signal value/month
Warm-Up Time
≥5min
Working Environment
-20~50℃, 15~90%RH non-condensing
Working Pressure
90~110kPa
Zero Drift
20ppm:≤±0.5ppm, 2000ppm:≤±4ppm
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for SULFUR-DIOXIDE-SENSOR. For a missing document or a specific revision, our experts send it to you.
Wall-mounted sulfur dioxide (SO2) sensor with an electrochemical cell, designed for real-time monitoring of gas concentrations in an indoor area.
Measure range0-20ppm/0-2000ppm
Average power consumption0.18W
Accuracy±5%FS or ±10%
Response time20ppm:≤45s, 2000ppm:≤70s
ModelRS-SO2*-*-2-*-T
2. Datasheet extract (recorded values)
Parameter
Value
Response time
20ppm:≤45s, 2000ppm:≤70s
Accuracy
±5%FS or ±10%
Average power consumption
0.18W
Measure range
0-20ppm/0-2000ppm
Model
RS-SO2*-*-2-*-T
Output signal
RS485/4-20mA/0-5V/0-10V
Power supply
10~30V DC
Repeatability
≤2%
Resolution
20ppm:0.1ppm, 2000ppm:1ppm
Stability
≤2% signal value/month
Warm-Up Time
≥5min
Working Environment
-20~50℃, 15~90%RH non-condensing
Working Pressure
90~110kPa
Zero Drift
20ppm:≤±0.5ppm, 2000ppm:≤±4ppm
Applications and use cases
Architectures in which SULFUR-DIOXIDE-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Answers to the questions that the recorded characteristics of SULFUR-DIOXIDE-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output signal": RS485/4-20mA/0-5V/0-10V.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details