RG-CS85-48GT4XS-HPD
Layer 3 core or aggregation switch, 48-port 1GE PoE

- Power supply and consumption
- RG-CS85-48GT4XS-HPD
- Real-time Clock (RTC)
- Supported
- Flash memory
- 4 GB
- Memory
- 2 GB
Layer 3 core or aggregation switch, 48-port 1GE PoE
Ruijie RG-CS85-48GT4XS-HPD Layer 3 switch for aggregation in large networks or core in small and medium-sized networks, with 48 10/100/1000BASE-T PoE/PoE+ ports and 4 1GE/10GE SFP+ ports.
Overview. The Ruijie RG-CS85-48GT4XS-HPD is a Layer 3 core or aggregation switch from the RG-CS85 series, designed for large enterprise networks as well as for small and medium-sized network cores.
Main characteristics. The switch provides 48 fixed 10/100/1000BASE-T ports supporting PoE and PoE+, plus 4 fixed 1GE/10GE SFP+ ports for uplinks. It offers a MAC address table of 64,000 entries, an ARP table of 24,000 entries, up to 12,000 IPv4 unicast routes and 3,000 IPv6 unicast routes, with 4 GB of flash memory and 2 GB of memory. A dual-core CPU clocked at 1.2 GHz handles processing.
Interfaces and connectivity. The chassis includes one RJ45 console port and one RJ45 MGMT port. An expansion slot accepts the CM85-4XS2CQ module, which adds 4 x 1GE/10GE SFP+ ports and 2 x 40GE/100GE QSFP28 ports. Device virtualization through Virtual Switching Unit (VSU) is supported, along with static IP routing, MPLS L3VPN and IGMP v1/v2/v3 multicast.
Power and environment. Maximum power consumption is 70 W excluding expansion modules and 95 W including them. Cooling is provided by fans with front-to-rear airflow, with two pre-installed fan modules in 2+1 redundancy. The operating altitude range is 0 m to 5,000 m, and the mean time between failures is 832,000 hours.
Typical uses. This switch suits aggregation in large networks and the core of small and medium-sized enterprise networks, with PoE/PoE+ power for connected devices. Management is available through SNMPv1/v2c/v3, CLI, RMON, Web, SSH, syslog, NTP and sFlow, and traffic mirroring through SPAN, RSPAN and ERSPAN.
Integration. IPv4 and IPv6 standard and extended ACLs, time-based ACLs and expert ACLs are available. The switch supports IEEE 802.1Q, 802.1X, 802.3af and 802.3ae standards, and 802.3ba (2010). Compatible SFP optical transceivers are listed in the manufacturer's range. The product is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for RG-CS85-48GT4XS-HPD, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL and QoS | Standard IP ACLs; Extended IP ACLs; Extended MAC ACLs; Time-based ACLs; Expert-level ACLs; ACL80; IPv6 ACL |
| Acoustic noise | 45°C (113°F): 57.9 dB |
| Altitude | Operating altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.); Storage altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.) |
| ARP table size | 24,000 |
| BootROM | 16 MB (2 flash chips for 1+1 boot redundancy) |
| Cable hot swapping | Supported |
| CM85-4XS2CQ | Expansion module, 4 x 1GE/10GE SFP+ ports and 2 x 40GE/100GE QSFP28 ports |
| Conformal Coating | Protects circuits against moisture, salt spray, mold, electrical shock and leakage, and so on |
| CPU | Dual-core CPU, each core with the clock speed of 1.2 GHz |
| Device virtualization | Virtual Switching Unit (VSU) |
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035,; EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,; EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| Energy saving | Supported |
| ESD | ESD Contact/Air Discharge: 6kV/8kV; ESD Susceptibility Contact/Air Discharge: 8 kV/15kV |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| Expansion Module | CM85-4XS2CQ |
| Fan | 2 x pluggable fan modules (pre-installed) |
| Fan Module | M2SFAN I-F (pre-installed 2) |
| Fan monitoring | Fan speed adjustment: 3 levels; Fan failure alarming |
| Fixed management port | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| Fixed service port | 48 x 10/100/1000BASE-T ports, supporting PoE/PoE+; 4 x 1GE/10GE SFP+ ports |
| Flash memory | 4 GB |
| GE-SFP-LH40-SM1310-BIDI | 1000BASE-LH, SFP transceiver, Tx1310/Rx1550, BiDi LC, 40 km over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1000BASE-LH, SFP transceiver, Tx1550/Rx1310, BiDi LC, 40 km over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1000BASE-LX, SFP transceiver, Tx1310/Rx1550, BiDi LC, 20 km over SMF |
| GE-SFP-LX20-SM1550-BIDI | 1000BASE-LX, SFP transceiver, Tx1550/Rx1310, BiDi LC, 20 km over SMF |
| Heat dissipation | Fan cooling, front-to-rear airflow |
| Humidity | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| IP Routing | Static routing |
| IP service | ARP |
| MAC address table size | 64,000 |
| Maximum Output Power | RG-PA150IB-F: 150 W |
| Maximum power consumption | 70 W (excluding expansion modules); 95 W (including expansion modules) |
| Mean Time Between Failure (MTBF) | 832,000 hours (about 95 years) |
| Memory | 2 GB |
| Mini-GBIC-GT | 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a; The port needs to be configured with auto-negotiation |
| MINI-GBIC-LH40-SM1310 | 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
| MINI-GBIC-LX-SM1310 | 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| MINI-GBIC-SX-MM850 | 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
| MINI-GBIC-ZX80-SM1550 | 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
| Module service port | CM85-4XS2CQ:; ● 4 x 1GE/10GE SFP+ ports; ● 2 x 40GE/100GE QSFP28 ports |
| Module slot | 1 x expansion module slot; 2 x power module slots; 2 x fan module slots |
| MPLS | MPLS L3VPN |
| Multicast | IGMP v1/v2/v3, and IGMP proxy |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| Number of ACEs | Ingress: 7,000; Egress:1,500 |
| Number of IPv4 multicast routes | 4,000 |
| Number of IPv4 unicast routes | 24,000 |
| Number of IPv6 multicast routes | 2,000 |
| Number of IPv6 unicast routes | 14,000 |
| Packet Forwarding Rate | 488 Mpps |
| PoE | IEEE 802.3af and 802.3at; Uninterruptible power supply upon hot start; Port priority |
| PoE output power | Each PoE port provides up to 30 W of power, with a maximum power of 1440 W over 48 ports (30 W x 48).; The maximum power depends on the configured power supply; ● 1 x RG-PA600I-P-F: 370 W; ● 2 x RG-PA600I-P-F: 740 W; ● 1 x RG-PA1000I-P-F: 740 W; ● 2 x RG-PA1000I-P-F: 1480 W, a maximum output of 1440 W over 48 ports (30 W x 48); Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device. |
| PoE port | All RJ45 ports support PoE/PoE+ (IEEE802.3af/at) power supply |
| PoE power cable pairs | Mode A (1-2, 3-6 pairs) |
| Power Input | RG-PA150IB-F (AC input):; ● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz; ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; ● Maximum input current: 3 A |
| Power Module | RG-PA600I-P-F; RG-PA1000I-P-F |
| Power module hot swapping | Supported |
| Power module redundancy | 1+1 power redundancy |
| Power supply | 2 x pluggable power modules |
| Power supply and consumption | RG-CS85-48GT4XS-HPD |
| Power supply monitoring | Monitoring of power supply model and status; Power supply failure alarming |
| Rack height | 1 RU |
| Real-time Clock (RTC) | Supported |
| Reliability | REUP, RLDP, DLDP |
| RG-CS85-24GT8XS-D | 24 x 10/100/1000BASE-T ports, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x built-in fixed fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-CS85-24SFP/8GT8XS-D | 24 x 1GE SFP ports (ports 1 to 16 are 100M/1GE SFP ports, ports 1 to 8 are 1GE SFP/RJ45 combo ports), 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x built-in fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-CS85-48GT4XS-D | 48 x 10/100/1000BASE-T ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x built-in fixed fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-CS85-48GT4XS-HPD | 48 x 10/100/1000BASE-T ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power module slots (Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module.) |
| RG-CS85-48SFP4XS-D | 48 x 1GE SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-PA1000I-P-F | 1000 W AC power module |
| RG-PA150IB-F | 150 W AC power module |
| RG-PA600I-P-F | 600 W AC power module |
| Safety regulation | IEC 62368-1 |
| Security | Multiple AAA modes |
| Surge Protection | MGMT port: 4 kV; Service port: 10 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Switch buffer | 4 MB |
| Switching Capacity | 656 Gbps |
| Temperature | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F) |
| Temperature Monitoring | Temperature monitoring, over-temperature alarming |
| Unit dimensions (W x D x H) | 442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.) |
| Unit Weight | 5.7 kg; (12.57 lbs) |
| USB | 1 x USB 3.0 port |
| USB hot swapping | Supported |
| XG-SFP-AOC1M | 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
| XG-SFP-AOC3M | 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
| XG-SFP-AOC5M | 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
| XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
| XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
| XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for RG-CS85-48GT4XS-HPD. For a missing document or a specific revision, our experts send it to you.
Ruijie RG-CS85-48GT4XS-HPD Layer 3 switch for aggregation in large networks or core in small and medium-sized networks, with 48 10/100/1000BASE-T PoE/PoE+ ports and 4 1GE/10GE SFP+ ports.
| Parameter | Value |
|---|---|
| ACL and QoS | Standard IP ACLs; Extended IP ACLs; Extended MAC ACLs; Time-based ACLs; Expert-level ACLs; ACL80; IPv6 ACL |
| Acoustic noise | 45°C (113°F): 57.9 dB |
| Altitude | Operating altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.); Storage altitude: 0 m to 5,000 m (0 ft. to 16,404.20 ft.) |
| ARP table size | 24,000 |
| BootROM | 16 MB (2 flash chips for 1+1 boot redundancy) |
| Cable hot swapping | Supported |
| CM85-4XS2CQ | Expansion module, 4 x 1GE/10GE SFP+ ports and 2 x 40GE/100GE QSFP28 ports |
| Conformal Coating | Protects circuits against moisture, salt spray, mold, electrical shock and leakage, and so on |
| CPU | Dual-core CPU, each core with the clock speed of 1.2 GHz |
| Device virtualization | Virtual Switching Unit (VSU) |
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035,; EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,; EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| Energy saving | Supported |
| ESD | ESD Contact/Air Discharge: 6kV/8kV; ESD Susceptibility Contact/Air Discharge: 8 kV/15kV |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| Expansion Module | CM85-4XS2CQ |
| Fan | 2 x pluggable fan modules (pre-installed) |
| Fan Module | M2SFAN I-F (pre-installed 2) |
| Fan monitoring | Fan speed adjustment: 3 levels; Fan failure alarming |
| Fixed management port | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| Fixed service port | 48 x 10/100/1000BASE-T ports, supporting PoE/PoE+; 4 x 1GE/10GE SFP+ ports |
| Flash memory | 4 GB |
| GE-SFP-LH40-SM1310-BIDI | 1000BASE-LH, SFP transceiver, Tx1310/Rx1550, BiDi LC, 40 km over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1000BASE-LH, SFP transceiver, Tx1550/Rx1310, BiDi LC, 40 km over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1000BASE-LX, SFP transceiver, Tx1310/Rx1550, BiDi LC, 20 km over SMF |
| GE-SFP-LX20-SM1550-BIDI | 1000BASE-LX, SFP transceiver, Tx1550/Rx1310, BiDi LC, 20 km over SMF |
| Heat dissipation | Fan cooling, front-to-rear airflow |
| Humidity | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| IP Routing | Static routing |
| IP service | ARP |
| MAC address table size | 64,000 |
| Maximum Output Power | RG-PA150IB-F: 150 W |
| Maximum power consumption | 70 W (excluding expansion modules); 95 W (including expansion modules) |
| Mean Time Between Failure (MTBF) | 832,000 hours (about 95 years) |
| Memory | 2 GB |
| Mini-GBIC-GT | 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a; The port needs to be configured with auto-negotiation |
| MINI-GBIC-LH40-SM1310 | 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
| MINI-GBIC-LX-SM1310 | 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| MINI-GBIC-SX-MM850 | 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
| MINI-GBIC-ZX80-SM1550 | 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
| Module service port | CM85-4XS2CQ:; ● 4 x 1GE/10GE SFP+ ports; ● 2 x 40GE/100GE QSFP28 ports |
| Module slot | 1 x expansion module slot; 2 x power module slots; 2 x fan module slots |
| MPLS | MPLS L3VPN |
| Multicast | IGMP v1/v2/v3, and IGMP proxy |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| Number of ACEs | Ingress: 7,000; Egress:1,500 |
| Number of IPv4 multicast routes | 4,000 |
| Number of IPv4 unicast routes | 24,000 |
| Number of IPv6 multicast routes | 2,000 |
| Number of IPv6 unicast routes | 14,000 |
| Packet Forwarding Rate | 488 Mpps |
| PoE | IEEE 802.3af and 802.3at; Uninterruptible power supply upon hot start; Port priority |
| PoE output power | Each PoE port provides up to 30 W of power, with a maximum power of 1440 W over 48 ports (30 W x 48).; The maximum power depends on the configured power supply; ● 1 x RG-PA600I-P-F: 370 W; ● 2 x RG-PA600I-P-F: 740 W; ● 1 x RG-PA1000I-P-F: 740 W; ● 2 x RG-PA1000I-P-F: 1480 W, a maximum output of 1440 W over 48 ports (30 W x 48); Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device. |
| PoE port | All RJ45 ports support PoE/PoE+ (IEEE802.3af/at) power supply |
| PoE power cable pairs | Mode A (1-2, 3-6 pairs) |
| Power Input | RG-PA150IB-F (AC input):; ● Rated input voltage: 100 V AC to 240 V AC, 50 Hz to 60 Hz; ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; ● Maximum input current: 3 A |
| Power Module | RG-PA600I-P-F; RG-PA1000I-P-F |
| Power module hot swapping | Supported |
| Power module redundancy | 1+1 power redundancy |
| Power supply | 2 x pluggable power modules |
| Power supply and consumption | RG-CS85-48GT4XS-HPD |
| Power supply monitoring | Monitoring of power supply model and status; Power supply failure alarming |
| Rack height | 1 RU |
| Real-time Clock (RTC) | Supported |
| Reliability | REUP, RLDP, DLDP |
| RG-CS85-24GT8XS-D | 24 x 10/100/1000BASE-T ports, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x built-in fixed fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-CS85-24SFP/8GT8XS-D | 24 x 1GE SFP ports (ports 1 to 16 are 100M/1GE SFP ports, ports 1 to 8 are 1GE SFP/RJ45 combo ports), 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x built-in fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-CS85-48GT4XS-D | 48 x 10/100/1000BASE-T ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x built-in fixed fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-CS85-48GT4XS-HPD | 48 x 10/100/1000BASE-T ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power module slots (Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module.) |
| RG-CS85-48SFP4XS-D | 48 x 1GE SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power module slots (Purchase at least one RG-PA150IB-F module.) |
| RG-PA1000I-P-F | 1000 W AC power module |
| RG-PA150IB-F | 150 W AC power module |
| RG-PA600I-P-F | 600 W AC power module |
| Safety regulation | IEC 62368-1 |
| Security | Multiple AAA modes |
| Surge Protection | MGMT port: 4 kV; Service port: 10 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Switch buffer | 4 MB |
| Switching Capacity | 656 Gbps |
| Temperature | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F) |
| Temperature Monitoring | Temperature monitoring, over-temperature alarming |
| Unit dimensions (W x D x H) | 442 mm x 420 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.) |
| Unit Weight | 5.7 kg; (12.57 lbs) |
| USB | 1 x USB 3.0 port |
| USB hot swapping | Supported |
| XG-SFP-AOC1M | 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
| XG-SFP-AOC3M | 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
| XG-SFP-AOC5M | 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
| XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
| XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
| XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
Answers to the questions that the recorded characteristics of RG-CS85-48GT4XS-HPD can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Ethernet switching": Jumbo frame (maximum length: 9,216 bytes).
Yes — recorded under "USB": 1 x USB 3.0 port.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Layer 3 core or aggregation switch, 48-port 1GE PoE

24-Port 1GE SFP Layer 3 Enterprise-Class Core or Aggregation Switch, 8-Port 10GE Uplink

24-Port Layer 3 Enterprise-Class Core or Aggregation Switch (with Eight Combo Ports), 8-Port 10GE Uplink

12-Port 1GE RJ45 Layer 3 Managed Access Switch with PoE+, 4-Port 10GE Uplink

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | RG-CS85-48GT4XS-HPD |
| Manufacturer | Ruijie |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details