RG-S5760C-48GT4XS-HP
Layer 3 core switch, 48 PoE/PoE+ ports, 10G uplink

- Power supply and consumption
- RG-S5760C-48GT4XS-HP-X
- Real-time Clock (RTC)
- Supported
- Flash memory
- 4 GB eMMC
- Memory
- 2 GB
Layer 3 core switch, 48 PoE/PoE+ ports, 10G uplink
Layer 3 core or aggregation switch for enterprise networks, with 48 10/100/1000BASE-T PoE/PoE+ ports and 4 1GE/10GE SFP+ uplink ports.
Overview. The Ruijie RG-S5760C-48GT4XS-HP-X is a Layer 3 core or aggregation switch for enterprise networks, with 48 10/100/1000BASE-T ports supporting PoE/PoE+ (IEEE 802.3af/at) and 4 1GE/10GE SFP+ uplink ports. It belongs to the RG-S5760C-X series.
Main characteristics. Dual-core CPU at 1.2 GHz, 2 GB memory, 4 GB eMMC flash and 16 MB BootROM with 1+1 redundancy. It supports static routing, MPLS L3VPN, jumbo frames up to 9,216 bytes and VSU device virtualization. Capacity of 64,000 MAC address entries, 24,000 IPv4 unicast routes and 1,000 SVIs.
Interfaces and connectivity. One RJ45 console port, one RJ45 MGMT port and an expansion slot for the M5000X-4XS2CQ module, which adds 4 1GE/10GE SFP+ ports and 2 40GE/100GE QSFP28 ports. SFP optical modules 1000BASE-LX, LH and ZX and the Mini-GBIC-GT copper transceiver are compatible. IGMP v1/v2/v3, SPAN, RSPAN and ERSPAN are supported, along with IP, MAC and IPv6 ACLs and AAA security.
Power and environment. Two hot-swappable power module slots in 1+1 redundancy, compatible with RG-PA600I-P-F or RG-PA1000I-P-F; maximum PoE output power reaches 1,440 W across 48 ports. Maximum power consumption is 70 W excluding expansion modules and 95 W including them. Front-to-rear airflow cooling with two fan modules in 1+1 redundancy. 1 RU rack height, operating and storage conditions as stated in the datasheet, compliant with RoHS and IEC 62368-1.
Typical uses. Aggregation of medium-sized local networks or core of small and medium-sized enterprise networks, powering PoE endpoints such as IP phones or cameras.
Integration. To provide connectivity to network equipment, plan the purchase of at least one RG-PA600I-P-F or RG-PA1000I-P-F power module; the M5000X-4XS2CQ expansion module requires software version 12.5(4)B0701 or later on V1.X switches.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for RG-S5760C-48GT4XS-HP, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL and QoS | Standard IP ACLs; Extended IP ACLs; Extended MAC ACLs; Time-based ACLs; Expert-level ACLs; ACL80; IPv6 ACL |
| Acoustic noise | 27°C (80.6°F): 53 dB; 45°C (113°F): 68 dB |
| Altitude | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.); Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) |
| BootROM | 16 MB (2 flash chips for 1+1 boot redundancy) |
| Cable hot swapping | Supported |
| CPU | Dual-core CPU, each core with the clock speed of 1.2 GHz |
| Device virtualization | VSU |
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| ESD | ESD contact/air discharge: 6 kV/8 kV; ESD susceptibility contact/air discharge: 8 kV/15 kV |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| Expansion Module | M5000X-4XS2CQ; Note: The V1.X switch needs to be upgraded to version 12.5(4)B0701 or later to support the expansion module. |
| Fan | 2 x pluggable fan modules |
| Fan Module | M2SFAN I-F (pre-installed 2) |
| Fan monitoring | Fan speed adjustment: 3 levels; Fan failure alarming |
| Fan redundancy | 1+1 redundancy |
| Fixed management port | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| Fixed service port | 48 x 10/100/1000BASE-T ports, supporting PoE/PoE+; 4 x 1GE/10GE SFP+ ports |
| Flash memory | 4 GB eMMC |
| GE-SFP-LH40-SM1310-BIDI | 1000BASE-LH, SFP transceiver, TX1310/RX1550, BiDi LC, 40 km over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1000BASE-LH, SFP transceiver, TX1550/RX1310, BiDi LC, 40 km over SMF |
| GE-SFP-LX03-SM1310-BIDI-I | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF |
| GE-SFP-LX03-SM1550-BIDI-I | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF |
| GE-SFP-LX20-SM1550-BIDI | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF |
| Heat dissipation | Fan cooling, front-to-rear airflow |
| Humidity | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| IP Routing | Static routing |
| IP service | ARP |
| M5000X-4XS2CQ | 4 x 1GE/10GE SFP+ ports, 2 x 40GE/100GE QSFP28 ports |
| Maximum number of ACEs | In: 75,000 Out:3,750 |
| Maximum number of ARP address entries | 24,000 |
| Maximum number of IGMP groups | 4,000 (3,000 in mmu-enhance mode) |
| Maximum number of IPv4 multicast routes | 4,000 (3,000 in mmu-enhance mode) |
| Maximum number of IPv4 unicast routes | 24,000 (shared with IPv6 routes) |
| Maximum number of IPv6 multicast routes | 2,000 (1,500 in mmu-enhance mode) |
| Maximum number of IPv6 unicast routes | 14,000 (shared with IPv4 routes) |
| Maximum number of MAC address entries | 64,000 |
| Maximum number of MLD groups | 2,000 (1,500 in mmu-enhance mode) |
| Maximum number of ND entries | 12,000 |
| Maximum number of SVIs | 1,000 |
| Maximum Output Power | RG-PA150IB-F: 150 W; RG-PD150IB-F: 150 W |
| Maximum power consumption | 70 W (excluding expansion modules); 95 W (including expansion modules) |
| Mean Time Between Failure (MTBF) | 811,680 hours (about 95 years) |
| Memory | 2 GB |
| Mini-GBIC-GT | 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a; The port needs to be configured with auto-negotiation |
| MINI-GBIC-LH40-SM1310 | 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
| MINI-GBIC-LX-SM1310 | 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| MINI-GBIC-SX-MM850 | 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
| MINI-GBIC-ZX80-SM1550 | 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
| Module slot | 1 x expansion module slot; 2 x power module slots; 2 x fan module slots |
| MPLS | MPLS L3VPN |
| Multicast | IGMP v1/v2/v3 and IGMP proxy |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| Performance and Capacity | RG-S5760C-X Series |
| PoE | RG-S5760C-48GT4XS-HP-E:; IEEE 802.3af and 802.3at, uninterruptible power supply upon hot start, and port priority |
| PoE output power | Each PoE port provides up to 30 W of power; The maximum power depends on the configured power supply; ● 1 x RG-PA600I-P-F: 370 W; ● 2 x RG-PA600I-P-F: 740 W; ● 1 x RG-PA1000I-P-F: 740 W; ● 2 x RG-PA1000I-P-F: 1480 W, a maximum output of 1440 W over 48 ports (30 W x 48); Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device. |
| PoE port | Ports 1 to 48 support PoE/PoE+ (IEEE 802.3af/at) power supply |
| PoE power cable pairs | Mode A (1-2, 3-6 pairs) |
| Power Input | RG-PA150IB-F (AC input):; ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz; ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; ● Maximum input current: 3 A; RG-PD150IB-F (DC input):; ● Rated input voltage: –48 V DC to –60 V DC; ● Maximum input voltage: –36 V DC to –75 V DC; ● Maximum input current: 5 A |
| Power Module | RG-PA600I-P-F; RG-PA1000I-P-F |
| Power module hot swapping | Supported |
| Power module redundancy | 1+1 redundancy |
| Power supply | 2 x pluggable power modules |
| Power supply and consumption | RG-S5760C-48GT4XS-HP-X |
| Power supply monitoring | Monitoring of the power supply model and status; Power supply failure alarming |
| Rack height | 1 RU |
| Real-time Clock (RTC) | Supported |
| Reliability | REUP, RLDP, and DLDP |
| RG-PA1000I-P-F | 1000 W AC power module |
| RG-PA150IB-F | 150 W AC power module |
| RG-PA600I-P-F | 600 W AC power module |
| RG-PD150IB-F | 150 W DC power module |
| RG-S5760C-24GT8XS-X | 24 x 10/100/1000BASE-T ports, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RG-S5760C-24SFP/8GT8XS-X | 24 x 1GE SFP ports (ports 1 to 16 support the rate of 100Mbps, ports 17 to 24 do not support the rate of 100Mbps, ports 1 to 8 are 10/100/1000BASE-T combo ports), 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RG-S5760C-48GT4XS-HP-X | 48 x 10/100/1000BASE-T ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power module slots; Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module. |
| RG-S5760C-48GT4XS-X | 48 x 10/100/1000BAST-T ports,4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RG-S5760C-48SFP4XS-X | 48 x 1GE SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 |
| Safety regulation | IEC 62368-1 |
| Security | AAA |
| Surge Protection | MGMT port: 4 kV; Service port: 10 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Switch buffer | 4 MB |
| System packet forwarding rate *1 | 586 Mpps |
| System switching capacity *2 | 787 Gbps |
| Temperature | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F) |
| Temperature Monitoring | Temperature monitoring, over-temperature alarming |
| Unit dimensions (W x D x H) | 442.0 mm x 420.0 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.) |
| Unit Weight | 5.5 kg (12.13 lbs) |
| USB | 1 x USB 2.0 port |
| USB hot swapping | Supported |
| VSU bandwidth | 260 Gbps |
| VXLAN | With VXLAN, a Layer 2 logical network can be built based on a Layer 3 network through software upgrade. |
| XG-SFP-AOC1M | 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
| XG-SFP-AOC3M | 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
| XG-SFP-AOC5M | 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
| XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
| XG-SFP-LR10-SM1270-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF |
| XG-SFP-LR10-SM1330-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF |
| XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
| XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
| XG-SFP-ZR-SM1550 | 10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for RG-S5760C-48GT4XS-HP. For a missing document or a specific revision, our experts send it to you.
Layer 3 core or aggregation switch for enterprise networks, with 48 10/100/1000BASE-T PoE/PoE+ ports and 4 1GE/10GE SFP+ uplink ports.
| Parameter | Value |
|---|---|
| ACL and QoS | Standard IP ACLs; Extended IP ACLs; Extended MAC ACLs; Time-based ACLs; Expert-level ACLs; ACL80; IPv6 ACL |
| Acoustic noise | 27°C (80.6°F): 53 dB; 45°C (113°F): 68 dB |
| Altitude | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.); Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) |
| BootROM | 16 MB (2 flash chips for 1+1 boot redundancy) |
| Cable hot swapping | Supported |
| CPU | Dual-core CPU, each core with the clock speed of 1.2 GHz |
| Device virtualization | VSU |
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| ESD | ESD contact/air discharge: 6 kV/8 kV; ESD susceptibility contact/air discharge: 8 kV/15 kV |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| Expansion Module | M5000X-4XS2CQ; Note: The V1.X switch needs to be upgraded to version 12.5(4)B0701 or later to support the expansion module. |
| Fan | 2 x pluggable fan modules |
| Fan Module | M2SFAN I-F (pre-installed 2) |
| Fan monitoring | Fan speed adjustment: 3 levels; Fan failure alarming |
| Fan redundancy | 1+1 redundancy |
| Fixed management port | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| Fixed service port | 48 x 10/100/1000BASE-T ports, supporting PoE/PoE+; 4 x 1GE/10GE SFP+ ports |
| Flash memory | 4 GB eMMC |
| GE-SFP-LH40-SM1310-BIDI | 1000BASE-LH, SFP transceiver, TX1310/RX1550, BiDi LC, 40 km over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1000BASE-LH, SFP transceiver, TX1550/RX1310, BiDi LC, 40 km over SMF |
| GE-SFP-LX03-SM1310-BIDI-I | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF |
| GE-SFP-LX03-SM1550-BIDI-I | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF |
| GE-SFP-LX20-SM1550-BIDI | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF |
| Heat dissipation | Fan cooling, front-to-rear airflow |
| Humidity | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| IP Routing | Static routing |
| IP service | ARP |
| M5000X-4XS2CQ | 4 x 1GE/10GE SFP+ ports, 2 x 40GE/100GE QSFP28 ports |
| Maximum number of ACEs | In: 75,000 Out:3,750 |
| Maximum number of ARP address entries | 24,000 |
| Maximum number of IGMP groups | 4,000 (3,000 in mmu-enhance mode) |
| Maximum number of IPv4 multicast routes | 4,000 (3,000 in mmu-enhance mode) |
| Maximum number of IPv4 unicast routes | 24,000 (shared with IPv6 routes) |
| Maximum number of IPv6 multicast routes | 2,000 (1,500 in mmu-enhance mode) |
| Maximum number of IPv6 unicast routes | 14,000 (shared with IPv4 routes) |
| Maximum number of MAC address entries | 64,000 |
| Maximum number of MLD groups | 2,000 (1,500 in mmu-enhance mode) |
| Maximum number of ND entries | 12,000 |
| Maximum number of SVIs | 1,000 |
| Maximum Output Power | RG-PA150IB-F: 150 W; RG-PD150IB-F: 150 W |
| Maximum power consumption | 70 W (excluding expansion modules); 95 W (including expansion modules) |
| Mean Time Between Failure (MTBF) | 811,680 hours (about 95 years) |
| Memory | 2 GB |
| Mini-GBIC-GT | 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a; The port needs to be configured with auto-negotiation |
| MINI-GBIC-LH40-SM1310 | 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
| MINI-GBIC-LX-SM1310 | 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| MINI-GBIC-SX-MM850 | 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
| MINI-GBIC-ZX80-SM1550 | 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
| Module slot | 1 x expansion module slot; 2 x power module slots; 2 x fan module slots |
| MPLS | MPLS L3VPN |
| Multicast | IGMP v1/v2/v3 and IGMP proxy |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| Performance and Capacity | RG-S5760C-X Series |
| PoE | RG-S5760C-48GT4XS-HP-E:; IEEE 802.3af and 802.3at, uninterruptible power supply upon hot start, and port priority |
| PoE output power | Each PoE port provides up to 30 W of power; The maximum power depends on the configured power supply; ● 1 x RG-PA600I-P-F: 370 W; ● 2 x RG-PA600I-P-F: 740 W; ● 1 x RG-PA1000I-P-F: 740 W; ● 2 x RG-PA1000I-P-F: 1480 W, a maximum output of 1440 W over 48 ports (30 W x 48); Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device. |
| PoE port | Ports 1 to 48 support PoE/PoE+ (IEEE 802.3af/at) power supply |
| PoE power cable pairs | Mode A (1-2, 3-6 pairs) |
| Power Input | RG-PA150IB-F (AC input):; ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz; ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; ● Maximum input current: 3 A; RG-PD150IB-F (DC input):; ● Rated input voltage: –48 V DC to –60 V DC; ● Maximum input voltage: –36 V DC to –75 V DC; ● Maximum input current: 5 A |
| Power Module | RG-PA600I-P-F; RG-PA1000I-P-F |
| Power module hot swapping | Supported |
| Power module redundancy | 1+1 redundancy |
| Power supply | 2 x pluggable power modules |
| Power supply and consumption | RG-S5760C-48GT4XS-HP-X |
| Power supply monitoring | Monitoring of the power supply model and status; Power supply failure alarming |
| Rack height | 1 RU |
| Real-time Clock (RTC) | Supported |
| Reliability | REUP, RLDP, and DLDP |
| RG-PA1000I-P-F | 1000 W AC power module |
| RG-PA150IB-F | 150 W AC power module |
| RG-PA600I-P-F | 600 W AC power module |
| RG-PD150IB-F | 150 W DC power module |
| RG-S5760C-24GT8XS-X | 24 x 10/100/1000BASE-T ports, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RG-S5760C-24SFP/8GT8XS-X | 24 x 1GE SFP ports (ports 1 to 16 support the rate of 100Mbps, ports 17 to 24 do not support the rate of 100Mbps, ports 1 to 8 are 10/100/1000BASE-T combo ports), 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RG-S5760C-48GT4XS-HP-X | 48 x 10/100/1000BASE-T ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power module slots; Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module. |
| RG-S5760C-48GT4XS-X | 48 x 10/100/1000BAST-T ports,4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RG-S5760C-48SFP4XS-X | 48 x 1GE SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power module slots.; Purchase at least one RG-PA150IB-F module. |
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 |
| Safety regulation | IEC 62368-1 |
| Security | AAA |
| Surge Protection | MGMT port: 4 kV; Service port: 10 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Switch buffer | 4 MB |
| System packet forwarding rate *1 | 586 Mpps |
| System switching capacity *2 | 787 Gbps |
| Temperature | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: –40°C to +70°C (–40°F to +158°F) |
| Temperature Monitoring | Temperature monitoring, over-temperature alarming |
| Unit dimensions (W x D x H) | 442.0 mm x 420.0 mm x 43.6 mm (17.40 in. x 16.54 in. x 1.72 in.) |
| Unit Weight | 5.5 kg (12.13 lbs) |
| USB | 1 x USB 2.0 port |
| USB hot swapping | Supported |
| VSU bandwidth | 260 Gbps |
| VXLAN | With VXLAN, a Layer 2 logical network can be built based on a Layer 3 network through software upgrade. |
| XG-SFP-AOC1M | 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
| XG-SFP-AOC3M | 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
| XG-SFP-AOC5M | 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
| XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
| XG-SFP-LR10-SM1270-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF |
| XG-SFP-LR10-SM1330-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF |
| XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
| XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
| XG-SFP-ZR-SM1550 | 10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF |
Answers to the questions that the recorded characteristics of RG-S5760C-48GT4XS-HP can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "VXLAN": With VXLAN, a Layer 2 logical network can be built based on a Layer 3 network through software upgrade..
Yes — recorded under "Ethernet switching": Jumbo frame (maximum length: 9,216 bytes).
Yes — recorded under "USB": 1 x USB 2.0 port.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Layer 3 core switch, 48 PoE/PoE+ ports, 10G uplink

24-Port Layer 3 Enterprise-Class Core or Aggregation Switch (with Eight Combo Ports), 8-Port 10GE Uplink

24-Port 1GE SFP Layer 3 Enterprise-Class Core or Aggregation Switch, 8-Port 10GE Uplink

RG-S5310-48SFP4XS-E, 48-Port GE Optical Layer 3 Managed Access Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | RG-S5760C-48GT4XS-HP |
| Manufacturer | Ruijie |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details