Seeed Studio non-invasive clamp-type AC current sensor with a 60 A AC rated input for a 1 V rated output. It measures current without interrupting the circuit.
Overview. The Seeed Studio non-invasive AC current transformer 60A-1V, reference 101990064, is an AC current sensor designed for non-contact measurement. It clamps around the target conductor, without any wiring modification or special tools.
Main characteristics. The rated input is 60 A AC, the rated output 1 V and the accuracy 1%. The open size is 13 mm x 13 mm and the sensor measures 78 mm x 62 mm x 25 mm, for a gross weight of 72 g.
Isolation and environment. The dielectric strength between output and housing is AC 3.5 kV for 1 minute at 50 Hz, providing galvanic isolation of the output. The working temperature ranges from -25 ℃ to +70 ℃. The waterproof grade is IP00, meaning the sensor is not protected against moisture or contact.
Connection. The output lead is 1 m long.
Typical uses. This sensor suits voltage measurement on circuits, monitoring and protection of AC motors, lighting equipment and air compressors.
Seeed Studio non-invasive clamp-type AC current sensor with a 60 A AC rated input for a 1 V rated output. It measures current without interrupting the circuit.
Architectures in which 101990064 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Associated system blocks
Energy metersCurrent sensorsData collection
Need a complete solution?
Send a request for 101990064 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details