Total solar radiation sensor with RS485 Modbus-RTU output, for measuring incident solar radiation in weather, agricultural and environmental monitoring stations.
Operating Temperature-30℃~75℃
Measuring Range0~2000W/㎡
Response time10ms
LinearityMaximum offset 1%
ProtocolMODBUS-RTU RS485
Resolution1W/㎡
Product overview
The Seeed Studio total solar radiation sensor measures global solar radiation across the 300 to 1100 nm spectral band, with a measuring range of 0 to 2000 W/m² and a resolution of 1 W/m². It reports its readings over an RS485 bus using the Modbus-RTU protocol, so it can be connected directly to a compatible data logger or PLC.
Response time and stability. The response time is 10 ms and the warm-up time is 4 s, allowing close-interval readings from power-up. Linearity deviates by a maximum of 1 %, and drift stays below 2 % within one year, which matters for series of measurements compared across seasons.
Power supply and installation environment — The supply accepts 5 to 24 V DC, with 12 V DC as the typical value. The enclosure is dust-tight and protected against water immersion to IP68, and the sensor operates between -30 °C and 75 °C, covering outdoor installations exposed continuously.
Applications. The sensor serves weather monitoring, agro-meteorological studies linked to crop growth and photosynthesis, environmental monitoring, and solar energy research, where knowledge of incident radiation determines installation output.
Total solar radiation sensor with RS485 Modbus-RTU output, for measuring incident solar radiation in weather, agricultural and environmental monitoring stations.
Operating Temperature-30℃~75℃
Measuring Range0~2000W/㎡
Response time10ms
LinearityMaximum offset 1%
ProtocolMODBUS-RTU RS485
2. Datasheet extract (recorded values)
Parameter
Value
Response time
10ms
Linearity
Maximum offset 1%
Measuring Range
0~2000W/㎡
Operating Temperature
-30℃~75℃
Protocol
MODBUS-RTU RS485
Resolution
1W/㎡
Response Spectrum
300~1100nm
Stability
Change<2% within one year
Supply V oltage
5 to 24V DC (12VDC typical)
Warm-Up Time
4s
Integration
Points to check before using 101991047 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -30℃~75℃ — check it against the installation environment.
Implementation checklist
Thermal : rated operating range -30℃~75℃ — check it against the installation environment.
Applications and use cases
Architectures in which 101991047 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
101991047
Total Solar Radiation Sensor with RS485 Modbus-RTU
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details