S-Soil MTEC-02B – Industrial soil moisture, temperature and EC sensor RS485

Industrial soil moisture, temperature and EC sensor RS485

Modular DIN-Rail Remote I/O Modules

  • -40℃ ~ +85℃
  • -40℃ ~ +80℃
  • RS-485
  • ± 0.5 ℃
Manufacturer part number
314990621
Manufacturer
Seeed Studio
Operating Temperature
-40℃ ~ +85℃
Range
-40℃ ~ +80℃

Industrial Seeed Studio S-Soil MTEC-02B sensor measuring soil volumetric water content, temperature and electrical conductivity at the same time, with Modbus-RTU RS485 output.

Product overview

Seeed Studio S-Soil MTEC-02B. industrial soil moisture, temperature and electrical conductivity (EC) sensor with Modbus-RTU RS485 output.

Measurements. The sensor combines three measurements in one probe: soil moisture (volumetric water content), soil temperature and soil electrical conductivity, which reflects the level of dissolved salts (TDS). The temperature range is -40 °C to +80 °C, with an accuracy of ± 0.5 °C and a resolution of 0.1 °C. Built-in temperature compensation operates from 0 to 50 °C. The measuring area is a cylinder of 7 cm diameter and 7 cm height around the probe.

Probe and enclosure. The anti-corrosion special electrode probe measures 70 mm in length and 3 mm in diameter. The PC enclosure and black flame-retardant epoxy resin sealing provide an IP68 protection rating. The device can be buried or inserted into the medium to be measured, and tolerates 0 to 100 %RH operating humidity, non-condensing.

Interfaces and power. The sensor communicates over MODBUS-RTU RS485 and is powered from 3.6 to 30 V DC, with a quiescent consumption of 6 mA at 24 V DC. The cable is 5 meters long and the aviation connector is waterproof. Data can be uploaded to the SenseCAP Portal or to a user's MQTT server.

Uses. This sensor suits soil environmental monitoring in industrial applications, in particular to connect the measurement to a PLC or gateway that supports Modbus-RTU RS485.

See all specifications

Highlights

  • IP rating: IP68
  • Accuracy: ± 0.5 ℃
  • Cable Length: 5 meters
  • Communication Protocol for Sensor: Modbus-RTU RS485
  • Cosine response: ≤10%(Deviation of sun height of 10° from ideal value on clear day)
  • Data Upload: SenseCAP Portal(default) User's Server (MQTT Server)

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40℃ ~ +85℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote