CFD400 1-meter coaxial RF cable connecting the SenseCAP M1 Indoor Gateway to a fiberglass antenna, with Type N female and RP-SMA male connectors.
Frequency Range0-6000MHz
Bend RadiusMin 25.4mm
Binder materialAluminum/PE Tape
Braid materialTinned copper wire
Capacitance76pF/m
Conductor MaterialCopper
Product overview
Seeed Studio CFD400. The Seeed Studio CFD400 RF cable, reference 321990875, is a 1-meter black coaxial cable with N female and RP-SMA male connectors, designed for the SenseCAP M1 Indoor Gateway and fiberglass antennas.
Main characteristics. The cable has 50 Ω impedance and covers 0-6000 MHz. Typical insertion loss is 0.15 dB at 900 MHz and at most 1.5 dB at 6 GHz. Typical VSWR is 1.1 at 900 MHz and at most 1.5 at 6 GHz. Capacitance is 76 pF/m and velocity of propagation is 85%.
Construction. The conductor is copper, the braid tinned copper wire, the binder aluminum/PE tape and the jacket PE. The external cable diameter is 10.3 mm and the minimum bend radius 25.4 mm. Length is 1 meter ±30 mm.
Durability and environment. Voltage breakdown is 2.5 kV, insulation resistance above 1,000 MΩ and mating cycles above 500. The cable operates from -30 °C to +65 °C and is RoHS compliant.
Typical uses. This cable connects an external antenna to a SenseCAP M1 Indoor LoRaWAN gateway while keeping RF losses low across the frequency range.
CFD400 1-meter coaxial RF cable connecting the SenseCAP M1 Indoor Gateway to a fiberglass antenna, with Type N female and RP-SMA male connectors.
Frequency Range0-6000MHz
Bend RadiusMin 25.4mm
Binder materialAluminum/PE Tape
Braid materialTinned copper wire
Capacitance76pF/m
2. Datasheet extract (recorded values)
Parameter
Value
Bend Radius
Min 25.4mm
Binder material
Aluminum/PE Tape
Braid material
Tinned copper wire
Capacitance
76pF/m
Conductor Material
Copper
Connectors
Type N Male/Jack; Type RP SMA Male
Environmental
RoHS
External cable diameter
10.3mm
Frequency Range
0-6000MHz
Impedance
50Ω
Insertion Loss
Typical 0.15db @ 900MHz; ≤1.5dB max @ 6GHz
Insulation Resistance
> 1,000 MΩ
Jacket Material
PE
Length
1 meter ±30mm
Mating Cycles
> 500
Operation Temperature
-30°C to +65°C
Velocity of Propagation
85%
Voltage breakdown
2.5KV
VSWR
Typical 1.1 @ 900MHz; ≤1.5 max @ 6GHz
Applications and use cases
Architectures in which 321990875 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for 321990875 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details