Overview. The Seeed Studio MIX8410 is an electrochemical oxygen sensor from the Grove range, designed to measure oxygen concentration in air. Under electrode catalysis, a redox reaction takes place at the working electrode and the counter electrode, generating a current that is measured to determine the concentration.
Main characteristics. Sensitivity of 0.1±0.03 mA with linear output, measurement range of 0 to 25%, repeatability of ±2% and response time below 10 s. The maximum overload is 30%.
Interfaces and power. Analog interface, input voltage of 3.3 V or 5 V. The maximum input voltage must not exceed 5.5 V. The solderless Grove system simplifies connection.
Power and environment. Working temperature range of -20 to 50 °C, storage range of 0 to 50 °C, operating humidity of 15 to 90% RH, non-condensing. The sensor should be preheated for 5 to 10 minutes before use and kept away from volatile solvents and acidic or alkaline environments.
Limitations. The sensor reflects an approximate trend of gas concentration within a permissible error range and does not give an exact value. For high-precision measurements, a dedicated instrument is recommended.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for MIX8410, with where it comes from. Use the filters to find one quickly.
All specifications (16)
Characteristic
Value
Response time
<10S
Input Voltage
3.3/5V
Interface
Analog
Maximum Overload
30%
Measurement Range
0-25%
Operating Humidity Range
15 ~ 90% RH, no-condensing
Power on aging time
30min
Repeatability
±2%
Same Bottom pin positions
The new version adopts an advanced anti-leakage technology, which greatly reduces the probability of leakage and solves the leakage problem of the old version.
Same driver board
The output current of the new version is lower, so the electrolyte consumption is slower and the sensor life is longer.
Same method of use
The output current of the new version is lower, so the electrolyte consumption is slower and the sensor life is longer.
Same physical dimensions
The output current of the new version is lower, so the electrolyte consumption is slower and the sensor life is longer.
Sensitivity
0.1±0.03 mA
Similarities
Differences
Storage Temperature Range
0 ~ 50˚C
Working Temperature Range
-20 - 50℃
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for MIX8410. For a missing document or a specific revision, our experts send it to you.
The new version adopts an advanced anti-leakage technology, which greatly reduces the probability of leakage and solves the leakage problem of the old version.
Same driver board
The output current of the new version is lower, so the electrolyte consumption is slower and the sensor life is longer.
Same method of use
The output current of the new version is lower, so the electrolyte consumption is slower and the sensor life is longer.
Same physical dimensions
The output current of the new version is lower, so the electrolyte consumption is slower and the sensor life is longer.
Sensitivity
0.1±0.03 mA
Similarities
Differences
Storage Temperature Range
0 ~ 50˚C
Working Temperature Range
-20 - 50℃
Applications and use cases
Architectures in which MIX8410 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for MIX8410 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
MIX8410
Electrochemical oxygen sensor Grove, analog output
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details