X2BP10XPB – Expansion board UPS with lead acid battery charging

Expansion board UPS with lead acid battery charging

Industrial UPS

  • -20…+60 °C
  • 0…1.5 A
  • 0…45 V
  • -30…+80 °C
Manufacturer part number
X2BP10XPB
Manufacturer
Sfera Labs
Operating Temperature
-20…+60 °C
Current Range
0…1.5 A

The Sfera Labs X2BP10XPB UPS expansion board provides battery backup from an external 12 V or 24 V lead acid or AGM battery for the Strato Pi Max server, with a software-controlled auxiliary output.

Product overview

Overview. The Sfera Labs X2BP10XPB UPS expansion board is an uninterruptible power supply for the Strato Pi Max server. It connects to an external lead acid or AGM battery, not included, which it charges itself.

Main characteristics. The board supports 12 V or 24 V batteries, with a suggested capacity of 1.2 Ah to 7 Ah. It protects the battery input against surges and reverse polarity with a 3.3 A resettable fuse. Maximum charge current is 500 mA for a 12 V battery and maximum charge voltage is 28.5 V for a 24 V battery. The switching threshold to battery mode is 7.5 V.

Monitoring and auxiliary output. Battery voltage and current are monitored. The software-controlled VSO auxiliary output powers external devices up to 1 A, protected by a 1.1 A resettable fuse. Front panel LEDs show charger status, power failure and auxiliary output status.

Power and environment. The input voltage range is 0 to 45 V. Operating temperature is -20 to +60 °C and storage temperature is -30 to +80 °C. Protection degree is IP20 and maximum altitude is 2000 m. The board complies with the electromagnetic immunity standards EN 61000-4-2 to EN 61000-4-6 and EN 61000-4-8.

Dimensions and integration. Dimensions are 84.3 × 41.1 × 10.5 mm and weight is 25 g, terminal block and screws included. Battery charging is managed by the RP2040 microcontroller, whose configuration can be adapted to other battery chemistries or charge profiles. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Altitude: Up to 2000 m
  • Current Range: 0…1.5 A
  • Humidity: 5% to 95% RH noncondensing
  • Operating Temperature: -20…+60 °C
  • Protection degree: IP20
  • Resolution: 12 bits (8.7 RP2040 ENOB)

Good to know before integrating

  • Thermal: rated operating range -20…+60 °C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Industrial UPS
Request a quote