JD194-BS4P
Active power transmitter with analog output and RS485

- Operating Temperature
- -40~70℃
- Safe Power Supply — Range
- AC 80~270V 50/60HZ,DC 100~350V
- Input Voltage
- rated value:AC 100v,220v,400v etc
- Input Current
- rated value:AC 1A,5A
Active power transmitter with analog output and RS485
Sfere JD194-BS4P active power transmitter for measuring active power, isolating the measurement and delivering an analog signal. Used in electric power installations and control systems.
Overview. The Sfere JD194-BS4P active power transmitter measures active power, provides isolated transmission and outputs an analog signal. It is intended for electric power installations, automatic control systems, dispatching systems and PLC control systems.
Main characteristics. Accuracy of 0.5%, data update rate of 1 s, rated input current AC 1 A or 5 A, rated input voltage AC 100 V, 220 V, 400 V etc., input frequency of 45 to 65 Hz, continuous overload of 2 times the rated value and insulation of at least 2 kVAC.
Interfaces and connectivity. Analog output DC 4 to 20 mA with load up to 350 Ω, or DC 0 to 5 V with load of at least 20 kΩ. RS485 port in 2-wire configuration with Modbus-RTU protocol up to 9600 bps.
Power and environment. Safe power supply AC 80 to 270 V 50/60 Hz or DC 100 to 350 V, consumption up to 5 VA. Operating temperature -40 to 70 ℃, storage temperature -40 to 85 ℃, relative humidity up to 93 %RH, altitude up to 2500 m.
Compliance. Compliant with EN61010-1:2010 and EN61326-1:2013, LVD and EMC (CE) certificate no. 0266/IN-IST-14.
Integration. The Modbus-RTU RS485 port allows connection to a PLC or a supervision system, while the analog output can feed a conventional control system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for JD194-BS4P, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | 0.5% |
| Altitude | ≤2500m |
| Analog Output | DC 4~20mA,load≤350Ω DC 0~5v,load≥20kΩ |
| Communcation | rs485 port,modbus-rtu,2 wire,up to 9600bps |
| Corresponding field: | electric power electrical installations automatic control system dispatching systems PLC control system |
| Data Update Rate | 1s |
| Input Current | rated value:AC 1A,5A |
| Input Frequency | 45~65HZ |
| Input — Overload | continuous:2 times of rated value |
| Input Voltage | rated value:AC 100v,220v,400v etc |
| Insulation | ≥2kVAC |
| Operating Temperature | -40~70℃ |
| Ref.Standard EN61010-1 | 2010; EN61326-1:2013 |
| Relative humidity | ≤93%RH |
| Safe Power Supply — Consumption | ≤5VA |
| Safe Power Supply — Range | AC 80~270V 50/60HZ,DC 100~350V |
| Storage Temperature | -40~85℃ |
| The Product Name: | JD194-BS4P Active power transmitter |
| The Product Type: | Transmitter |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for JD194-BS4P. For a missing document or a specific revision, our experts send it to you.
Sfere JD194-BS4P active power transmitter for measuring active power, isolating the measurement and delivering an analog signal. Used in electric power installations and control systems.
| Parameter | Value |
|---|---|
| Accuracy | 0.5% |
| Altitude | ≤2500m |
| Analog Output | DC 4~20mA,load≤350Ω DC 0~5v,load≥20kΩ |
| Communcation | rs485 port,modbus-rtu,2 wire,up to 9600bps |
| Corresponding field: | electric power electrical installations automatic control system dispatching systems PLC control system |
| Data Update Rate | 1s |
| Input Current | rated value:AC 1A,5A |
| Input Frequency | 45~65HZ |
| Input — Overload | continuous:2 times of rated value |
| Input Voltage | rated value:AC 100v,220v,400v etc |
| Insulation | ≥2kVAC |
| Operating Temperature | -40~70℃ |
| Ref.Standard EN61010-1 | 2010; EN61326-1:2013 |
| Relative humidity | ≤93%RH |
| Safe Power Supply — Consumption | ≤5VA |
| Safe Power Supply — Range | AC 80~270V 50/60HZ,DC 100~350V |
| Storage Temperature | -40~85℃ |
| The Product Name: | JD194-BS4P Active power transmitter |
| The Product Type: | Transmitter |
Points to check before using JD194-BS4P in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Input Current | rated value:AC 1A,5A |
| Input Voltage | rated value:AC 100v,220v,400v etc |
| Safe Power Supply — Consumption | ≤5VA |
| Safe Power Supply — Range | AC 80~270V 50/60HZ,DC 100~350V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of JD194-BS4P can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communcation": rs485 port,modbus-rtu,2 wire,up to 9600bps.
Yes — recorded under "Communcation": rs485 port,modbus-rtu,2 wire,up to 9600bps.
-40~70℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Active power transmitter with analog output and RS485

Single phase current transmitter

three phase current transmitter

Reactive power transmitter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | JD194-BS4P |
| Manufacturer | Sfere |
Energy Monitoring Devices
Reactive power transmitter, DIN rail mounted · Ref. : JD194-BS4Q
Price on request
Energy Monitoring Devices
IP53 LoRaWAN Single-Phase Current Meter 150 A · Ref. : 1-PHASE
Price on request
Energy Monitoring Devices
Three-phase smart energy sensor with LoRa-MESH
Price on request
Energy Monitoring Devices
ZigBee Smart Plug with Energy Metering 32 A · Ref. : NR12
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details