Sino-Inst electromagnetic flow meter for partially filled pipes, DN200-DN6000mm, 0.05-10m/s, 4-20mA, optional RS232/RS485.
Pressure range1.6MPa
Measuring RangeFlow velocity 0.05-10m/s
Digital communication interface:RS232、RS485 optional
Current output signal:4-20mA/DC (load resistance ≤500Ω)
Conductivity of measured medium:≥20s/cm
Lining type:Polyfluorobutanil, PTFE
Product overview
This Sino-Inst electromagnetic flow meter measures flow in pipes that the medium does not fill or only partially fills. It covers circular pipes DN200-DN6000mm and rectangular channels up to 6m wide, for velocities of 0.05-10m/s and conductivity ≥20s/cm.
Stated accuracy is ±2mm on water level and ±1.0% to ±1.5% on flow. The medium can range from -25 to 80℃ at 1.6MPa. Electrodes are available in 316L, HaB, HaC, titanium, tantalum or platinum-iridium alloy, and the lining in PTFE.
The backlit LCD shows instantaneous flow, velocity, totalised flow and level. Outputs are 4-20mA (load ≤500Ω) and 1-2000HZ pulse, with optional RS232 or RS485 and GSM/GPRS wireless transmission. Power is 220VAC, 12VDC or 24VDC; the sensor can be IP68.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for ELECTROMAGNETIC PARTIALLY FILLED PIPE FLOW METER, with where it comes from. Use the filters to find one quickly.
All specifications (18)
Characteristic
Value
Pressure range
1.6MPa
Applicable Medium
The medium cannot fill the pipe, or partially fill the pipe
Conductivity of measured medium:
≥20s/cm
Current output signal:
4-20mA/DC (load resistance ≤500Ω)
Digital communication interface:
RS232、RS485 optional
Display
Large screen, backlight LCD display, which can simultaneously display instantaneous flow, flow rate, cumulative flow, liquid level and other measurement data
Official documents and the technical data recorded for ELECTROMAGNETIC PARTIALLY FILLED PIPE FLOW METER. For a missing document or a specific revision, our experts send it to you.
Sino-Inst electromagnetic flow meter for partially filled pipes, DN200-DN6000mm, 0.05-10m/s, 4-20mA, optional RS232/RS485.
Pressure range1.6MPa
Measuring RangeFlow velocity 0.05-10m/s
Digital communication interface:RS232、RS485 optional
Current output signal:4-20mA/DC (load resistance ≤500Ω)
Conductivity of measured medium:≥20s/cm
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
1.6MPa
Applicable Medium
The medium cannot fill the pipe, or partially fill the pipe
Conductivity of measured medium:
≥20s/cm
Current output signal:
4-20mA/DC (load resistance ≤500Ω)
Digital communication interface:
RS232、RS485 optional
Display
Large screen, backlight LCD display, which can simultaneously display instantaneous flow, flow rate, cumulative flow, liquid level and other measurement data
Architectures in which ELECTROMAGNETIC PARTIALLY FILLED PIPE FLOW METER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Answers to the questions that the recorded characteristics of ELECTROMAGNETIC PARTIALLY FILLED PIPE FLOW METER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Digital communication interface:": RS232、RS485 optional.
2Does it support RS-232?
Yes — recorded under "Digital communication interface:": RS232、RS485 optional.
3Does it support CAN bus?
Yes — recorded under "Display": Large screen, backlight LCD display, which can simultaneously display instantaneous flow, flow rate, cumulative flow, liquid level and other measurement data.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSino-Inst
ELECTROMAGNETIC PARTIALLY FILLED PIPE FLOW METER
Electromagnetic flow meter for partially filled pipes
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details