Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.

ELECTROSTATIC CAPACITIVE LEVEL SWITCH – Electrostatic Capacitive Level Switch with SPDT Relay

Electrostatic Capacitive Level Switch with SPDT Relay

Level Transmitters

Manufacturer part number
ELECTROSTATIC CAPACITIVE LEVEL SWITCH
Manufacturer
Sino-Inst

Sino-Inst electrostatic capacitive level switch for detecting the level of liquids, powders, granules and mixed media, with no moving parts and a 5A/250VAC SPDT relay output.

Product overview

Sino-Inst. Electrostatic Capacitive Level Switch, a capacitive probe level switch designed to signal the presence or absence of material in a tank. It works on a resonant circuit principle: the probe and the tank wall act as the two plates of a capacitor, and material contact changes the capacitance, which triggers the output.

Main characteristics. Adjustable sensitivity from 0.5 pF to 750 pF with one-button calibration, adjustable delay from 0 to 30 s, and SPDT relay output rated 5A/250VAC. The junction box is aluminum alloy with a baked paint finish, and the protection rating is IP65.

Connection and probe. Process connection by G1" thread or 1" PT, or by flange or chuck on request. The probe is SUS304 with PTFE insulation, customizable to 316L or PTFE coating.

Power and environment. Power supply 220VAC or 24VDC, electrical interface M20x1.5. Operating temperature -20 to 120 °C, up to 235 °C in the high-temperature version, and atmospheric operating pressure, up to 2.5 MPa in the high-pressure version.

Typical uses. Level detection of liquids such as solvents, fuels, water and pure water, factory wastewater, wastewater, domestic sewage and rainwater, as well as powders (dust, sand, flour, sugar, lime powder, cement) and granules (feed, medicine, plastic particles). The product also suits oil-water interfaces and detection of sediments.

Integration. Installation is relatively simple, but the probe must be in direct contact with the medium and the container wall. Measurement accuracy is lower and is highly affected by the dielectric constant, static electricity, temperature and humidity; frequent cleaning of material buildup is necessary. Available on quotation from Atlas Electronics.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Level Transmitters
Request a quote