SI-3101 – Electromagnetic water flow meter for industrial water

Electromagnetic water flow meter for industrial water

General Industrial Sensors & Transmitters

  • ±0.5%
  • -25ºC ~ +60ºC
  • DN6~DN3000mm
  • 0.3~15m/s
Manufacturer part number
SI-3101
Manufacturer
Sino-Inst
Measuring Range
1500:1,flow rate <15m/s
Accuracy
±0.5%

The Sino-Inst SI-3101 electromagnetic flow meter measures the volumetric flow of conductive liquids in closed pipes, for industrial water, sewage and slurry.

Product overview

Sino-Inst SI-3101, digital electromagnetic flow meter — the SI-3101 is a Sino-Inst electromagnetic flow meter for measuring the volumetric flow of conductive liquids in closed pipes. It is suited to domestic water, industrial water, raw water, ground water, urban and industrial sewage, as well as pulp and slurry.

Main characteristics. Accuracy of ±0.5% of the displayed value, ±0.3% or ±0.2% optional. Measuring range of 1500:1 at flow rates below 15 m/s. Nominal diameter from DN6 to DN3000 mm. Medium conductivity of at least 20 µS/cm. Display of instantaneous flow, total flow and percentage of flow, with alarm display and four thin-film touch buttons for setting. Forward and reverse totalisers with an anti-failure clock that stores 16 power failure records (10 years).

Interfaces and connectivity. Isolated bidirectional analog output 0-10 mA or 4-20 mA, frequency output from 1 to 5000 Hz for forward and reverse flow, pulse output up to 5000 CP/S, and two alarm outputs from photoelectric isolated transistors. RS232, RS485 or HART communication optional.

Power and environment. Power supply AC220V 50 Hz or DC24V, power consumption below 15 W. Medium temperature -20 ºC to +70 ºC, ambient temperature -25 ºC to +60 ºC, ambient humidity 5 to 100% RH. Protection class IP65, IP67, or IP68 optional. Nominal pressure 0.6 to 4.0 MPa. Integral, remote, submersible or ex-proof structure depending on the model.

Typical uses. The SI-3101 suits online process water and industrial water measurement, monitoring of treatment plants and effluents, and measurement of pulp and slurry containing solid particles. Its RS485 and pulp outputs allow integration into a supervision system or a PLC.

Integration. The lining and electrode material (316L, Hastelloy, titanium, tantalum, etc.) must be matched to the measured medium; 316L electrodes are not suitable for acids and alkaline salts.

See all specifications

Highlights

  • Accumulator: Forward total quantity, reverse total quantity
  • Accuracy: ±0.5%
  • Ambient Humidity: 5~100%RH(relative humidity)
  • Ambient temperature: -25ºC ~ +60ºC
  • Damping time constant: Continuous variable from 0-100 s (90%)can be selected by group
  • Diameter: DN6~DN3000mm

Typical applications

Derived from the part category, not a compatibility statement.