Insertion electromagnetic flow meter measuring the volumetric flow of conductive liquids in large-diameter closed pipes, with installation possible under pressure.
Power consumption10W (matching power consumption)
Usage environment — Storage temperature-20~+40℃
Accuracy LevelMeasurement error
Casing materialSilicon aluminum alloy
Connection Method≤1.6MPa
DiameterFlow range
Product overview
The Sino-Inst SI-3107 is an insertion electromagnetic flow meter, based on Faraday's law of electromagnetic induction, designed to measure the volumetric flow of conductive liquids in closed pipes from DN100 to DN3000. — Measuring principle — The sensor uses low-frequency square wave excitation, giving a stable zero point and strong resistance to interference. Measurement accuracy is unaffected by changes in temperature, pressure, density or conductivity of the fluid. — Installation — The unit is inserted through a full port ball valve, so the sensor can be retracted without stopping the flow or draining the system. The insertion depth is adjustable according to pipe diameter, and a depth gauge is supplied. An optional hot tap installation kit is available for pressurized pipes. — Measurement and display — The meter measures forward and reverse flow. A dot-matrix LCD shows cumulative flow on 8 digits, instantaneous flow on 4 digits and flow percentage. An EEPROM retains parameters and totals during power outages. — Outputs and connectivity — Analog output 4-20 mA, pulse output in Hz and RS-485 communication, with RS232, M-BUS or HART optional. — Power and environment — Working power supply AC110V to AC245V, power consumption 10 W, protection IP65 (IP68 for the split submersible type), medium temperature below 70 ℃ for the one-piece version, ambient temperature -20 to +60 ℃. — Typical uses — Raw water measurement in large-diameter pipes, for example monitoring withdrawn volumes, with RS-485 output allowing connection to a PLC or a supervision system. — Accuracy — ±2.0% of the range for 0 to 0.1 m/s, ±1.5% for 0.1 to 0.5 m/s and ±1.0 to ±1.5% for 0.5 to 10 m/s, over 40% to 100% of full scale.
Insertion electromagnetic flow meter measuring the volumetric flow of conductive liquids in large-diameter closed pipes, with installation possible under pressure.
Power consumption10W (matching power consumption)
Usage environment — Storage temperature-20~+40℃
Accuracy LevelMeasurement error
Casing materialSilicon aluminum alloy
Connection Method≤1.6MPa
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy Level
Measurement error
Casing material
Silicon aluminum alloy
Connection Method
≤1.6MPa
Diameter
Flow range
Display content — Cumulative total
8 digits
Display content — Flow rate
4 digits
Display content — Instantaneous flow
4 digits
DN150mm
6.3615 m³/h
DN200mm
11.3094 m³/h
DN250mm
17.6709 m³/h
DN300mm
25.4462 m³/h
DN350mm
34.6350 m³/h
DN400mm
45.2376 m³/h
DN500mm
70.6838 m³/h
DN600mm
101.7846 m³/h
DN700mm
138.5402 m³/h
DN800mm
180.9504 m³/h
DN900mm
229.0154 m³/h
Electrode material
316L stainless steel
Flow rate — 0~0.1m/s
±2.0% of the range (40%~100% of the full range)
Flow rate — 0.1~0.5m/s
±1.5% of the range (40%~100% of the full range)
Flow rate — 0.5~10m/s
±1.0~±1.5% of the range (calibration can reach ±1.0%)
Measurable pipe diameter
DN100~DN3000
Medium temperature — One-piece
<70℃
NO
SI-Magnetic Water Flow Meter
Output signal — Analog; output
4-20mA
Output Signal — Communication
RS-485Optional RS232, M-BUS, HART)
Output signal — Pulse output
Hz
Power consumption
10W (matching power consumption)
Pressure level — Split type
<120℃
Probe Material
304 stainless steel
Probe structure
Stainless steel/PTFE lining
Product origin
China
Protection level — Large ball valve optional
Flange connection
Protection level — One-piece type
IP65
Protection level — Simple type
Flange connection
Protection level — Split type
IP65 (IP68 submersible type)
Protection level — With ball valve insert type
With welded short pipe
Protective Level
IP65
T/T, PayPal
T/T, Paypal
Usage environment — Ambient humidity
5%~90%
Usage environment — Ambient temperature
-20~+60℃
Usage environment — Storage temperature
-20~+40℃
Working Power Supply
AC110V~AC245V
Applications and use cases
Architectures in which SI-3107 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSino-Inst
SI-3107
Insertion electromagnetic flow meter for large water pipes
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details