The Sino-Inst SI-3205 turbine flow meter measures the flow of non-corrosive, low-velocity liquids free of impurities, with pulse, 4-20 mA, RS485 Modbus-RTU or HART outputs.
Temp. Range-200~+180℃
Accuracy0.5% or 1.0% of Reading
High Accuracy0.5% or 1.0% of Reading
DiameterDN2~DN100
Diameter and installationFlange connection DN15-DN200
Explosion-proofExdIIBT6 (explosion proof type)
Product overview
Overview. The Sino-Inst SI-3205 is a threaded connection turbine flow meter, an in-line digital flow sensor designed to measure non-corrosive, low-velocity liquids free of impurities. It is not suitable for gas or steam.
Main characteristics. Accuracy of 0.5% or 1.0% of reading, turn down ratio of 10:1, compact construction in 304 or 316 stainless steel. Sizes from DN2 to DN100 and a pressure rating of 1.6 MPa. The fluid temperature range extends from -200 °C to +180 °C depending on the specification, the default standard type T1 covering -20 °C to +80 °C.
Interfaces and connectivity. Pulse output, 4-20 mA analog output, RS485 with Modbus-RTU protocol and HART. Threaded connection G or NPT, and flange connections to GB/T 9119-2010, DIN, ANSI and JIS standards.
Power and environment. Ingress protection IP65, and IP68 under another specification. Operating temperature from -20 °C to +60 °C. Explosion-proof version Exd II BT6 available.
Typical uses. Flow measurement of clean liquids in industrial processes, with data transmitted to a PLC or supervision system over RS485 Modbus-RTU or HART.
Integration. Wiring and output configuration should be checked against the ordering code selected. Each reference is configured on quotation.
The Sino-Inst SI-3205 turbine flow meter measures the flow of non-corrosive, low-velocity liquids free of impurities, with pulse, 4-20 mA, RS485 Modbus-RTU or HART outputs.
Temp. Range-200~+180℃
Accuracy0.5% or 1.0% of Reading
High Accuracy0.5% or 1.0% of Reading
DiameterDN2~DN100
Diameter and installationFlange connection DN15-DN200
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
0.5% or 1.0% of Reading
Diameter
DN2~DN100
Diameter and installation
Flange connection DN15-DN200
Explosion-proof
ExdIIBT6 (explosion proof type)
Flange standard
GB/T 9119-2010, DIN, ANSI, JIS
High Accuracy
0.5% or 1.0% of Reading
Ingress Protection
IP65
Large turn down ratio
10:1
Material
304 or 316 stainless steel, all stainless steel flow meter
Medium
Non-corrosive low velocity liquid without impurity,not suitable for gas/steam
Medium temperature
Default type T1: -20℃~+80℃ (Standard)
Operation condition
Operating temperature: -20℃~+60℃
Output
Pulse, 4-20mA analog output,; RS485 (Modbus-RTU protocol), HART
Pressure
1.6 MPa
Protection
IP65, IP68
Temp. Range
-200~+180℃
Applications and use cases
Architectures in which SI-3205 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSino-Inst
SI-3205
Threaded Connection Turbine Flow Meter for Liquids
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details