SI-3502 thermal mass flow meter measuring dry air and most gas flows directly, for monitoring compressed air networks and detecting leaks.
Operating temp. — Transmitter-20~+45℃
Temp. Range-40~200℃
Accuracy±1.5%
Response time1s
DiameterDN10~DN4000mm
DisplayCompact type: 4 lines LCD display
Product overview
Overview. The Sino-Inst SI-3502 is a thermal mass flow meter that directly measures the flow of dry air and gases (except acetylene) using the heat diffusion principle. This method requires no temperature, pressure or density compensation.
Main characteristics. Accuracy of ±1.5%, response time of 1 s, flow range of 0.5 to 100 m/s and a range ratio of 100:1, allowing very low flows to be detected for leak detection. The sensor accepts pipe diameters from DN10 to DN4000 mm, with an insert type for large diameters.
Interfaces and connectivity. Optically isolated 4-20 mA output (maximum load 500 Ω), optically isolated RS485 output and HART output. The meter thus integrates with the automation and supervision systems of the facility.
Display. Compact 4-line LCD showing mass flow, standard volume flow, accumulated flow, medium temperature and standard flow.
Power and environment. 24 VDC supply for the compact version, which also accepts 220 VAC at a maximum of 18 W, and 220 VAC at a maximum of 19 W for the remote version. Sensor operating temperature of -10 to +200 °C (default type) or up to 350 °C (high temperature type), transmitter operating temperature of -20 to +45 °C. Operating pressure up to 4 MPa, IP67 protection for the sensor part, stainless steel SUS304 housing.
Typical uses. Monitoring and measuring consumption in compressed air networks, control of non-corrosive gases such as oxygen, nitrogen and carbon dioxide, and leak detection.
Integration. No moving parts and no pressure-sensing parts, which ensures good vibration resistance and simple installation and maintenance.
SI-3502 thermal mass flow meter measuring dry air and most gas flows directly, for monitoring compressed air networks and detecting leaks.
Operating temp. — Transmitter-20~+45℃
Temp. Range-40~200℃
Accuracy±1.5%
Response time1s
DiameterDN10~DN4000mm
2. Datasheet extract (recorded values)
Parameter
Value
Response time
1s
Accuracy
±1.5%
Diameter
DN10~DN4000mm
Display
Compact type: 4 lines LCD display
Display content
Mass flow, standard volume flow, accumulated flow, time, accumulated time, medium temp., standard flow, etc.
Flow rate
0.5-100m/s
Housing Material
A SUS304
Ingress Protection
IP67 (sensor part)
Medium
All gases (except acetylene)
Operating pressure — Medium pressure≤10MPa
Medium pressure≤2.5MPa
Operating temp. — Sensor
Default type: -10~+200℃High temp. type: -10~350℃
Operating temp. — Transmitter
-20~+45℃
Output
HART
Output — 4-20mA
Optical isolation, max. load 500Ω
Output — RS485
Optical isolation
Pipe Diameter
C Round pipe: DN15~DN6000
Pipe diameter — DN10-80 (Flange type)
DN100-4000 ( Insert type)
Pipe Material
Carbon steel, stainless steel, plastic, etc.
Power
DC 24VDC
Power supply — Compact type
DC24V or AC220V≤18W
Power supply — Remote type
AC220V≤19W
Pressure
Max 4MPa
Protection
IP67 (sensor part)
Sensor material — Stainless steel
Stainless / carbon steel
Sensor Type
C Retrench pattern insert type
SI-3502
Thermal mass flow meter
TEMP
I 10~200℃
Temp. Range
-40~200℃
Integration
Points to check before using SI-3502 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range Default type: -10~+200℃High temp. type: -10~350℃ — check it against the installation environment.
2Thermalrated operating range -20~+45℃ — check it against the installation environment.
Power and communication
Power
DC 24VDC
Power supply — Compact type
DC24V or AC220V≤18W
Power supply — Remote type
AC220V≤19W
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range Default type: -10~+200℃High temp. type: -10~350℃ — check it against the installation environment.
Thermal : rated operating range -20~+45℃ — check it against the installation environment.
Applications and use cases
Architectures in which SI-3502 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSino-Inst
SI-3502
Thermal mass flow meter for compressed air and gases
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details