C2P-PN-04B-A05 – PROFINET valve terminal with 4 double solenoid valves

PROFINET valve terminal with 4 double solenoid valves

Industrial Automation Systems

  • -5~+50℃
  • RJ45
  • Supported
  • 30mA
Manufacturer part number
C2P-PN-04B-A05
Manufacturer
Solidot
Operating Temperature
-5~+50℃
Fieldbus Interface
RJ45

The C2P-PN-04B-A05 is a Solidot PROFINET pneumatic valve terminal fitted with 4 double solenoid valves compatible with AirTAC-7V1, for driving pneumatic actuators from a PROFINET network.

Product overview

Solidot C2P-PN-04B-A05 PROFINET valve terminal — The Solidot C2P-PN-04B-A05 is a PROFINET bus valve terminal that can be equipped with 4 double solenoid valves of the AirTAC-7V1 series. The customised base plate is made of fully integrated all-aluminium alloy.

Main characteristics. The terminal combines 4 double solenoid valves on a compact modular base (136.5 × 90 × 65 mm). It provides open circuit and short circuit diagnostics per channel, as well as channel short circuit protection. Its weight varies by product model.

Connectivity. The PROFINET bus is connected through 2 RJ45 connectors supporting cascading communication, at a transmission rate of 100 Mb/s. UTP or STP cable of category 5 or higher is accepted, STP being recommended, over a transmission distance of 100 m or less. The terminal is electrically isolated.

Power and environment. Power is supplied at 18 to 36 VDC through 5-pin push-in terminal blocks, with reverse polarity protection and power interface surge protection. The rated current consumption is 30 mA. The housing is rated IP20 and operates between -5 and +50 °C, with storage between -20 and +75 °C, and a relative humidity of 95 % without condensation.

Typical uses and integration. The terminal is intended for driving pneumatic actuators from a PROFINET PLC or controller. Remote diagnosis reduces troubleshooting difficulties, and simple wiring allows quick installation and easy maintenance.

See all specifications

Highlights

  • Dimensions: 136.5*90*65mm
  • Bus connection method: 2*RJ45
  • Bus Protocol: PROFINET
  • Channel Open Circuit Diagnostics: Supported
  • Channel short circuit diagnostics: Supported
  • Channel short circuit protection: Supported

Good to know before integrating

  • Thermal: rated operating range -5~+50℃ — check it against the installation environment.