C2S-CB-24B-A01 – CC-Link IE Field Basic valve terminal for 24 double solenoid valves

CC-Link IE Field Basic valve terminal for 24 double solenoid valves

Pneumatic Valves and Manifolds

  • -5~+50℃
  • M12
  • Supported
  • 30mA
Manufacturer part number
C2S-CB-24B-A01
Manufacturer
Solidot
Operating Temperature
-5~+50℃
Fieldbus Interface
M12

Solidot CC-Link IE Field Basic valve terminal driving 24 AirTAC-4V1 double solenoid valves, with M12 connectors and channel diagnostics.

Product overview

Overview. The Solidot C2S-CB-24B-A01 is a CC-Link IE Field Basic valve terminal designed to drive up to 24 double solenoid valves of the AirTAC-4V1 series. Its base plate is fully integrated in all-aluminium alloy and its modular structure occupies little space.

Main characteristics. The product measures 346.5 × 90 × 65 mm and operates at a transmission rate of 100 Mb/s over a distance of up to 100 m. It is powered from 18 to 36 VDC with a rated current consumption of 30 mA and has an IP20 protection rating.

Interfaces and connectivity. The bus is connected through two M12 4-pin D-coded female connectors, which allows cascading between modules. Power is supplied through an M12 5-pin A-coded male connector. The recommended transmission medium is UTP or STP cable of Category 5 or higher, with STP recommended.

Diagnostics and protection. The terminal provides channel open circuit and short circuit diagnostics, channel short circuit protection, reverse polarity protection and power interface surge protection. Electrical isolation is provided and remote diagnosis reduces troubleshooting effort.

Power and environment. The operating temperature range is -5 to +50 °C and the storage range is -20 to +75 °C, with a relative humidity of 95 % without condensation.

Typical use. This terminal integrates into a CC-Link IE Field Basic network to control pneumatic solenoid valves and report their diagnostics to the controller.

See all specifications

Highlights

  • Dimensions: 346.5*90*65mm
  • Bus connection method: 2 x M12, 4-pin, D-code, female connector (socket)
  • Bus Protocol: CC-Link IE Field Basic
  • Channel Open Circuit Diagnostics: Supported
  • Channel short circuit diagnostics: Supported
  • Channel short circuit protection: Supported

Good to know before integrating

  • Thermal: rated operating range -5~+50℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote