C2S-EI-24B-A07 – 24-channel EtherNet/IP valve terminal, double solenoid

24-channel EtherNet/IP valve terminal, double solenoid

Pneumatic Valves and Manifolds

  • -5~+50℃
  • M12
  • Supported
  • 30mA
Manufacturer part number
C2S-EI-24B-A07
Manufacturer
Solidot
Operating Temperature
-5~+50℃
Fieldbus Interface
M12

Solidot C2S-EI-24B-A07 EtherNet/IP valve terminal, equipped for up to 24 AirTAC-5V1 double solenoid valves to control pneumatic cylinders and actuators.

Product overview

Overview. The Solidot C2S-EI-24B-A07 is an EtherNet/IP valve terminal from the C2S-EI series, with a customized base plate in fully integrated all-aluminium alloy. It can be fitted with 24 double solenoid valves and supports AirTAC-5V1 series valves.

Main characteristics. The terminal has a modular structure and occupies little space. Its simple wiring and quick installation make maintenance easier. Its dimensions are 346.5 × 90 × 65 mm.

Interfaces and connectivity. The EtherNet/IP bus is connected through 2 M12 4-pin D-coded female connectors, at a transmission rate of 100 Mb/s and a maximum distance of 100 m. The recommended transmission medium is UTP or STP Category 5 or higher, STP being preferred. The module supports cascading communication and remote diagnosis.

Power and environment. The power supply is 18 to 36 VDC, through an M12 5-pin A-coded male connector. The rated current consumption is 30 mA. The product provides electrical isolation, reverse polarity protection and power interface surge protection, as well as channel open circuit and short circuit diagnostics and channel short circuit protection. Protection rating IP20, operating temperature -5 to +50 ℃, storage temperature -20 to +75 ℃, relative humidity 95 % without condensation.

Typical use and integration. Through its EtherNet/IP bus, the terminal connects to a PLC or an industrial gateway to drive the solenoid valves remotely and diagnose faults.

See all specifications

Highlights

  • Dimensions: 346.5*90*65mm
  • Bus connection method: 2 x M12, 4-pin, D-code, female connector (socket)
  • Bus Protocol: EtherNet/IP
  • Channel Open Circuit Diagnostics: Supported
  • Channel short circuit diagnostics: Supported
  • Channel short circuit protection: Supported

Good to know before integrating

  • Thermal: rated operating range -5~+50℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.