XB6S-CB2002-C – CC-Link IE Field Basic bus coupler with built-in Ethernet switch

CC-Link IE Field Basic bus coupler with built-in Ethernet switch

Industrial Ethernet Switches, PoE & TSN Networking

  • -40~80℃
  • 95 %, no condensation
  • 106.4*43*61mm
  • 2*RJ45
Manufacturer part number
XB6S-CB2002-C
Manufacturer
Solidot
Operating Temperature
-40~80℃
Storage Temperature
95 %, no condensation

The Solidot XB6S-CB2002-C is a CC-Link IE Field Basic bus coupler with a built-in Ethernet switch, used to connect I/O modules to a PLC over an Ethernet bus.

Product overview

Overview. The Solidot XB6S-CB2002-C is a CC-Link IE Field Basic bus coupler with a built-in Ethernet switch, linking digital, analog and motion control I/O modules to a PLC over an industrial Ethernet network.

Main characteristics. The coupler offers a minimum cycle time of 1 ms and supports up to 1024 bytes of input and output process data. It includes module fault auto-recovery. It provides a 2000 mA drive circuit for the coupler and the subsequent I/O modules. Its dimensions are 106.4 × 43 × 61 mm and it weighs 140 g.

Interfaces and connectivity. Two RJ45 bus connections provide the Ethernet links, with a transmission rate of 100 Mb/s, a station-to-station distance of 100 m and Ethernet CAT5 cabling. The module connects to its internal bus through an X-bus backplane.

Power and environment. The power supply is 24 VDC (18 V to 36 V). The operating temperature range is -40 to 80 °C, and the storage conditions are listed as 95 % relative humidity, no condensation. The protection rating is given as IP20 in the manufacturer's description.

Typical uses. This coupler extends an automation station with digital, analog or motion control I/O modules while limiting the number of network nodes used. It is compatible with Mitsubishi FX5U, L and IQ-R PLCs and with mainstream CC-Link IE Field Basic master stations.

Integration. Configuration is simple and wiring is made through pluggable 3-pin spring-cage terminals.

See all specifications

Highlights

  • Dimensions: 106.4*43*61mm
  • Bus connection method: 2*RJ45
  • Bus Protocol: CC-Link IE Field Basic
  • Data transmission medium: Ethernet CAT5 Cable
  • Input/Output Process Data Size: 1024Bytes
  • Minimum cycle time: 1ms

Good to know before integrating

  • Thermal: rated operating range -40~80℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote