XB6S-CT2002 – CC-Link IE TSN fieldbus coupler for remote I/O

CC-Link IE TSN fieldbus coupler for remote I/O

Modular DIN-Rail Remote I/O Modules

Manufacturer part number
XB6S-CT2002
Manufacturer
Solidot

DIN-rail CC-Link IE TSN coupler linking up to 32 slave stations and 1024 remote I/O points to a CC-Link IE TSN master.

Product overview

Overview. The Solidot XB6S-CT2002 is a CC-Link IE TSN fieldbus coupler module for DIN-rail mounting. It acts as the interface between a CC-Link IE TSN master and remote input-output modules, whether digital, analog or motion control.

Main characteristics. The coupler provides a 2000 mA drive circuit for itself and for the I/O modules that follow it. It supports up to 32 slots and 1024 points per coupler, with a transmission rate of 1 Gbps and a station-to-station distance of 100 m. It supports high-speed X-bus communication with up to 32 slave stations at full load.

Interfaces and connectivity. The module has two RJ45 bus connections, with Ethernet cabling compliant with Category 5 (CAT5) of EN 50173 or ISO/IEC 11801. It is compatible with mainstream CC-Link IE TSN master stations, including those from Mitsubishi. The 3-pin spring-cage power connector and fast pluggable terminal blocks allow tool-free wiring.

Power and environment. The power input is SELV 24 V DC (18 to 36 V), with electrical isolation. The module operates from -20 to +60 °C, stores from -40 to +80 °C, tolerates 95 % relative humidity non-condensing and has an IP20 protection rating. Its dimensions are 106.4 x 43 x 61 mm and its weight is 160 g.

Diagnostics and maintenance. The module supports diagnostics, alarms, module fault auto-recovery and firmware upgrade.

Integration. The coupler fits into a CC-Link IE TSN automation architecture to extend remote inputs and outputs on a DIN rail.

Typical applications

Derived from the part category, not a compatibility statement.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.