The Solidot XB6S-EC2002 is an EtherCAT coupler for DIN-rail remote input-output modules, linking the EtherCAT network to X-bus I/O modules.
Operating Temperature-20... +60 °C
Storage Temperature-40... +80 °C
Dimensions106.4 x 43 x 61 mm
AlarmSupported
Bus connection method2 x RJ45
Bus ProtocolEtherCAT
Product overview
Overview. The Solidot XB6S-EC2002 is an EtherCAT fieldbus coupler, a DIN-rail remote input-output module designed to connect I/O modules to an EtherCAT network.
Main characteristics. The module handles 1024 bytes of input/output process data with a minimum cycle time of 250 µs. It supports PDO access via SDO, diagnostics, alarm, firmware upgrade and automatic module fault recovery.
Interfaces and connectivity. The coupler has two RJ45 bus connections, operating at 100 Mb/s over Ethernet CAT5 cable with a transmission distance of 100 m station to station.
Power and environment. It is powered from 24 V DC (18... 36 V) through a 3-pin spring-loaded connector. It operates between -20 and +60 °C, stores between -40 and +80 °C, tolerates 95 % relative humidity non-condensing and has an IP20 protection rating. Dimensions: 106.4 x 43 x 61 mm; weight: 155 g.
Typical use and integration. Suited to EtherCAT automation architectures requiring remote extension of input-output points. The manufacturer's text states compatibility with EtherCAT master stations such as TwinCAT, CODESYS and Omron.
The Solidot XB6S-EC2002 is an EtherCAT coupler for DIN-rail remote input-output modules, linking the EtherCAT network to X-bus I/O modules.
Operating Temperature-20... +60 °C
Storage Temperature-40... +80 °C
Dimensions106.4 x 43 x 61 mm
AlarmSupported
Bus connection method2 x RJ45
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
106.4 x 43 x 61 mm
Alarm
Supported
Bus connection method
2 x RJ45
Bus Protocol
EtherCAT
Data transmission medium
Ethernet CAT5 Cable
Diagnostics
Supported
Firmware Upgrade
Supported
Input/Output Process Data Size
1024 bytes
Minimum cycle time
250 µs
Module Fault Auto-Recovery
Supported
Operating Temperature
-20... +60 °C
PDO access via SDO
Supported
Power Connection Method
3-pin spring-loaded connector
Power supply
24 V DC (18... 36 V)
Protection rating
IP20
Relative humidity
95 %, non-condensing
Storage Temperature
-40... +80 °C
Transmission Distance
100 m (station-to-station distance)
Transmission Rate
100 Mb/s
Weight
155 g
Integration
Points to check before using XB6S-EC2002 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20... +60 °C — check it against the installation environment.
Power and communication
Power Connection Method
3-pin spring-loaded connector
Power supply
24 V DC (18... 36 V)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20... +60 °C — check it against the installation environment.
Applications and use cases
Architectures in which XB6S-EC2002 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details