XB6S-MT2002-C – Modbus TCP coupler for DIN-rail remote I/O modules

Modbus TCP coupler for DIN-rail remote I/O modules

Modular DIN-Rail Remote I/O Modules

  • -40~80℃
  • 95 %, no condensation
  • 106.4*43*61mm
  • Supported
Manufacturer part number
XB6S-MT2002-C
Manufacturer
Solidot
Operating Temperature
-40~80℃
Storage Temperature
95 %, no condensation

Solidot XB6S-MT2002-C Modbus TCP coupler on DIN rail, linking up to 32 I/O modules through an internal X-bus. It integrates with Modbus TCP master controllers.

Product overview

Overview. The Solidot XB6S-MT2002-C is a Modbus TCP fieldbus coupler for modular I/O systems mounted on DIN rail. It acts as a gateway between the Ethernet network and the I/O modules connected to its X-bus backplane.

Main characteristics. The coupler supports up to 32 slave stations and 1024 points, with a minimum cycle time of 1 ms. It supplies 2000 mA of current to itself and to the following I/O modules. Input/output process data size reaches 512 bytes. The module supports firmware upgrade and automatic recovery after a module fault.

Interfaces and connectivity. The coupler provides two RJ45 connectors for the Modbus TCP bus, with a transmission rate of 100 Mb/s over Ethernet CAT5 cable and a station-to-station distance of up to 100 m. Power is connected through a removable 3-pin spring-cage terminal block.

Power and environment. It runs from 24 VDC (18 V to 36 V). Its operating temperature range is -40 to 80 °C, and its protection rating is given as IP20 in the manufacturer documentation. Dimensions are 106.4 × 43 × 61 mm and weight is 140 g.

Typical uses. This coupler suits extending a Modbus TCP PLC or supervision system with digital, analog or motion control I/O modules.

Integration. The product is delivered without special configuration and is set up with the tools provided by the manufacturer. It is available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Dimensions: 106.4*43*61mm
  • Alarm: Supported
  • Bus connection method: 2*RJ45
  • Bus Protocol: Modbus TCP
  • Data transmission medium: Ethernet CAT5 Cable
  • Firmware Upgrade: Supported

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40~80℃ — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote