The Sollae Systems CIE-H10G is a DIN-rail remote I/O gateway with 8 isolated digital inputs and 8 relay outputs rated 5A, controllable over Modbus/TCP.
Sollae Systems CIE-H10G, DIN-rail remote I/O controller — the CIE-H10G is a remote I/O gateway combining 8 digital inputs and 8 relay outputs in a single module.
Main characteristics. The inputs are isolated by photocoupler (dry contact, WET) with a maximum input voltage of DC 24V and an input voltage of DC 5V. The relay outputs handle 5A at DC 28V resistive load. The module draws 450mA typical and provides an LED per input and per output.
Interfaces and connectivity. The 10Base-T/100Base-TX Ethernet RJ45 interface supports an IPv4/IPv6 dual stack and the protocols Modbus/TCP, HTTP, TCP, UDP and ICMPv6/TCPv6/UDPv6. I/O can be controlled through Modbus/TCP, HTTP, serialized Modbus/TCP or macro. An RS232 port on a DSUB 9-pin male connector, from 300bps to 230,400bps, works as a serial-to-Ethernet converter in TCP Server, TCP Client, UDP and ATC modes. IP and MAC filtering restricts access to given hosts or networks.
Power and environment. The unit measures 153mm x 126mm x 32mm, weighs approximately 475g and operates from -40°C to +70°C, with storage up to +85°C. It complies with CE (EMC 2014/30/EU, RoHS 2011/65/EU) and is KC registered (KN 32, KN 35).
Typical uses and integration. With its RS232 port and Modbus/TCP support, the module connects serial equipment to an Ethernet network and exchanges data with a PLC or supervisory system. Configuration is done with the ezManager tool for Windows, and I/O controllers are managed with ModMap.
The Sollae Systems CIE-H10G is a DIN-rail remote I/O gateway with 8 isolated digital inputs and 8 relay outputs rated 5A, controllable over Modbus/TCP.
1, 2(※ a single idle bit is automatically added to every stop bit by the MCU function)
Storage Temperature
-40°C ~ +85°C
System LED
PWR, STS, LINK, RXD, TXD
Weight
Approximately 475g
Integration
Points to check before using CIE-H10G in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C ~ +70°C — check it against the installation environment.
Power and communication
Current consumption
450mA typical
Input Voltage
DC 5V
Maximum Input Voltage
DC 24V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C ~ +70°C — check it against the installation environment.
Applications and use cases
Architectures in which CIE-H10G can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details