SMG-5620
Industrial RS232/422/485 to Modbus TCP gateway

- Operating Temperature
- -40°C ~ +85°C
- Network Interface
- 10Base-T/100Base-TX Ethernet(RJ45)
- Serial Interface
- RS232 - RXD, TXD, RTS, CTS, GND
- Input Voltage
- Terminal Block: 8.5V ~ 38V
Industrial RS232/422/485 to Modbus TCP gateway
Protocol Gateways, Serial Device Servers & CAN Adapters
The Sollae SMG-5620 industrial gateway converts Modbus RTU and Modbus ASCII frames to Modbus TCP, connecting serial devices to an Ethernet network.
Overview. The Sollae Systems SMG-5620 is an industrial gateway converting Modbus RTU and Modbus ASCII to Modbus TCP, designed to integrate serial devices into an Ethernet network.
Main characteristics. The serial port, selectable as RS232, RS422 or RS485, uses a 9 pin D-sub male connector and is electrically isolated at 2500Vrms for 1 minute. Baud rate ranges from 1,200 to 230,400 bps, with 7 or 8 data bits, 1 or 2 stop bits and None, Even, Odd, Mark and Space parity.
Interfaces and connectivity. The 10Base-T/100Base-TX Ethernet interface (RJ45) operates with an IPv4/IPv6 dual stack. Security relies on password and SSL/TLS. The spFinder tool provides configuration and monitoring over the network. PWR, STS, MTX, MRX, STX and SRX LEDs show the operating status.
Power and environment. The terminal block input accepts 8.5V to 38V. Typical consumption is 2W at DC 12V and 1.6W at DC 5V. The case measures 158mm x 90mm x 24mm and weighs about 364g. It operates from -40°C to +85°C, with storage over the same temperature range.
Compliance. The product carries CE markings (EMC 2014/30/EU and RoHS 2011/65/EU) and KC registration (KN 32, KN 35).
Integration. The RS485 or RS232 port connects PLCs or Modbus RTU devices, the gateway making them accessible over Modbus TCP on the network.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SMG-5620, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Current consumption | Typically, 2W at DC 12V and 1.6W at DC 5V |
| Baudrate | 1,200bps ~ 230,400bps |
| BRACKET_BLACK | Datasheet |
| CE | EMC 2014/30/EU, RoHS 2011/65/EU |
| Connector | 9 pin D-sub male |
| Data Bits | 8bits, 7bits |
| Input Voltage | Terminal Block: 8.5V ~ 38V |
| Isolation | Electrically isolated (2500Vrms for 1 minute) |
| KC | Registration(KN 32, KN 35) |
| LED | PWR, STS, MTX, MRX, STX, SRX |
| MOUNTER | Datasheet |
| Network Interface | 10Base-T/100Base-TX Ethernet(RJ45) |
| Operating Temperature | -40°C ~ +85°C |
| Optional Accessories — Description | Note |
| Parity | None, Even, Odd, Mark, Space |
| Part Number — Description | Note |
| Protocols | IPv4/IPv6 dual stack |
| Security | Password, SSL/TLS |
| Serial Interface | RS232 - RXD, TXD, RTS, CTS, GND |
| Size | 158mm x 90mm x 24mm |
| SMG-5620-BO | SMG-5620 |
| spFinder | Configuration and Monitoring Tool through Network |
| Stop Bit | 1, 2 |
| Storage Temperature | -40°C ~ +85°C |
| Weight | About 364g |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for SMG-5620. For a missing document or a specific revision, our experts send it to you.
The Sollae SMG-5620 industrial gateway converts Modbus RTU and Modbus ASCII frames to Modbus TCP, connecting serial devices to an Ethernet network.
| Parameter | Value |
|---|---|
| Current consumption | Typically, 2W at DC 12V and 1.6W at DC 5V |
| Baudrate | 1,200bps ~ 230,400bps |
| BRACKET_BLACK | Datasheet |
| CE | EMC 2014/30/EU, RoHS 2011/65/EU |
| Connector | 9 pin D-sub male |
| Data Bits | 8bits, 7bits |
| Input Voltage | Terminal Block: 8.5V ~ 38V |
| Isolation | Electrically isolated (2500Vrms for 1 minute) |
| KC | Registration(KN 32, KN 35) |
| LED | PWR, STS, MTX, MRX, STX, SRX |
| MOUNTER | Datasheet |
| Network Interface | 10Base-T/100Base-TX Ethernet(RJ45) |
| Operating Temperature | -40°C ~ +85°C |
| Optional Accessories — Description | Note |
| Parity | None, Even, Odd, Mark, Space |
| Part Number — Description | Note |
| Protocols | IPv4/IPv6 dual stack |
| Security | Password, SSL/TLS |
| Serial Interface | RS232 - RXD, TXD, RTS, CTS, GND |
| Size | 158mm x 90mm x 24mm |
| SMG-5620-BO | SMG-5620 |
| spFinder | Configuration and Monitoring Tool through Network |
| Stop Bit | 1, 2 |
| Storage Temperature | -40°C ~ +85°C |
| Weight | About 364g |
Points to check before using SMG-5620 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Current consumption | Typically, 2W at DC 12V and 1.6W at DC 5V |
| Input Voltage | Terminal Block: 8.5V ~ 38V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of SMG-5620 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Serial Interface": RS232 - RXD, TXD, RTS, CTS, GND.
Yes — recorded under "Network Interface": 10Base-T/100Base-TX Ethernet(RJ45).
-40°C ~ +85°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Industrial RS232/422/485 to Modbus TCP gateway

/ RS232 Modbus Gateway

/ Wireless LAN Modbus Gateway

/ RS422/485 Modbus Gateway

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SMG-5620 |
| Manufacturer | Sollae Systems |
Protocol Gateways, Serial Device Servers & CAN Adapters
Wireless LAN Modbus gateway, IEEE 802.11b/g · Ref. : SMG-5400
Price on request
Protocol Gateways, Serial Device Servers & CAN Adapters
Integrated M2M Gateway with OPC UA, 4G LTE and CNC · Ref. : CPS-MG341G5-ADSC1-931
Price on request
Protocol Gateways, Serial Device Servers & CAN Adapters