BPS3000 – Battery pre-diagnosis system for energy storage

Battery pre-diagnosis system for energy storage

Energy Gateways

  • 10 ℃ ~ 30 ℃
  • 1700 W
  • IEC60870-5-104
  • ≤ 4000 m
Manufacturer part number
BPS3000
Manufacturer
Sungrow
Operating Temperature Range
10 ℃ ~ 30 ℃
Power consumption
1700 W

The Sungrow BPS3000 is a battery pre-diagnosis system for utility-scale energy storage plants. It detects faulty battery cells and anticipates consistency drift before it affects capacity.

Product overview

Sungrow BPS3000. the BPS3000 is a battery pre-diagnosis system from Sungrow, designed for utility-scale energy storage plants.

Main functions. The system provides five-dimensional health diagnostics: voltage, temperature and capacity consistency evaluation, internal resistance analysis and Type I abnormal depletion fault analysis. It issues three-level early warnings, including voltage inconsistency, Type I and Type II abnormal depletion pre-alarms, and provides online cell analysis and intelligent maintenance suggestions. A diagnostic report can be generated within one minute.

Communication and connectivity. The BPS3000 communicates over optical fiber or Ethernet using the IEC60870-5-104 protocol. It can be deployed in bus, star or ring network topologies.

Power and environment. It operates on 100 Vac to 240 Vac, 50 Hz or 60 Hz, with a power consumption of 1700 W. Its operating temperature range is 10 ℃ to 30 ℃, its humidity range 10 % to 90 % non-condensing, and its operating altitude up to 4000 m. Its protection class is IP20.

Configuration and integration. The system includes rack servers and a switch, with an optional UPS and firewall. Its dimensions are 800 mm × 2260 mm × 1000 mm.

Typical uses. Thanks to the IEC60870-5-104 protocol, the BPS3000 can integrate with a plant supervision system to report battery alarms and cell-level health status in real time.

See all specifications

Highlights

  • AC input: 100 Vac - 240 Vac , 50 Hz / 60 Hz
  • Communication medium: Optical fiber / Ethernet
  • Communication Protocol: IEC60870-5-104
  • Configuration: Rack servers, Switch, UPS ( Optional ), Firewall ( Optional )
  • Dimensions (W x H x D): 800 mm * 2260 mm * 1000 mm
  • Networking method: Bus type/ Star type/ Ring type

Good to know before integrating

  • Thermal: rated operating range 10 ℃ ~ 30 ℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.