ST2236UX – Liquid-Cooled LFP Battery Energy Storage Container

Liquid-Cooled LFP Battery Energy Storage Container

Rack Energy Storage

  • 1123 V ~ 1500 V
  • RS485, Ethernet
  • 50 Hz / 60 Hz
  • 2236 kWh
Manufacturer part number
PDP-B TYPE-ST2236UX
Manufacturer
Sungrow
Battery Voltage Range
1123 V ~ 1500 V
Communication interfaces
RS485, Ethernet

Liquid-cooled LFP battery energy storage container with 2236 kWh capacity, designed for utility-scale stationary storage and equipped with an SC4000UD-MV PCS and an integrated 4000 kVA transformer.

Product overview

Sungrow PDP-B Type-ST2236UX. liquid-cooled LFP battery energy storage system (BESS) container with an SC4000UD-MV power conversion system (PCS). Overview — The ST2236UX is a fully pre-assembled battery energy storage system with a capacity of 2236 kWh (BOL) per unit and a DC energy of 4472 kWh for the two units supplied. No battery module handling is required on site, which simplifies transport and operation. Main characteristics — Battery voltage range from 1123 V to 1500 V, adjustable power factor from 1.0 leading to 1.0 lagging, power factor above 0.99 at nominal power and current total harmonic distortion below 3 % at nominal power. Liquid cooling of the battery chamber provides higher efficiency and longer battery cycle life. The 4000 kVA transformer uses ONAN cooling, with PCB-free mineral oil or degradable oil on request. Interfaces and connectivity — The system provides RS485 and Ethernet ports and supports the Modbus RTU and Modbus TCP protocols for integration into a supervisory system. Fast state monitoring and fault recording enable pre-alarm and fault location. Power and environment — LV/MV voltage of 0.8 kV / 33 kV. Grid frequency range of 45 Hz to 55 Hz and 55 Hz to 65 Hz, nominal grid frequency 50 Hz or 60 Hz. Operating temperature from -30 °C to 50 °C with derating above 45 °C, relative humidity from 0 % to 95 % non-condensing, maximum working altitude 3000 m. The battery cabinet has IP 54 protection. Safety — Fused sprinkler heads, explosion prevention and ventilation for IDLH gases according to NFPA 69, DC circuit with fast breaking and anti-arc protection, and multi-level battery protection layers. Compliance — CE, IEC 62477-1, IEC 61000-6-2, IEC 61000-6-4, IEC 62619. Battery unit dimensions 9340 mm x 2600 mm x 1730 mm, weight 24,000 kg. Typical uses — Utility-scale stationary storage connected to the medium-voltage grid, controllable via Modbus from a supervisory system. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Adjustable power factor: 1.0 leading ~ 1.0 lagging
  • Battery capacity (BOL): 2236 kWh
  • Battery Voltage Range: 1123 V ~ 1500 V
  • BOL kWh (DC): 4,472 kWh
  • Cell type: LFP
  • Communication interfaces: RS485, Ethernet

Good to know before integrating

  • Thermal: rated operating range -30 ℃ ~ 50 ℃ ( > 45 ℃ derating ) — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote