The Sunricher SR-BL9032A-PIR-D is a PIR sensor controller integrated into the luminaire, linking DALI presence detection to a Bluetooth mesh network for lighting control.
Product overview
Overview. The Sunricher SR-BL9032A-PIR-D is a DALI BLE PIR sensor controller, designed to be integrated into the luminaire, that converts Bluetooth signals into DALI signals.
Main characteristics. The product works on a Bluetooth® mesh network: received signals are relayed to neighbouring devices, which extends the control distance. All devices on the DALI line are broadcast controlled from a mobile application. Its maximum power consumption on the DALI line is 30 mA.
Interfaces and connectivity. The controller has an on-board antenna and supports kinetic energy switches and EnOcean switches EWSSB and EWSDB. In a typical indoor environment, the typical wireless communication range is 20 m to 25 m, the actual range depending on field installation. A magnetic reset is available: touch the top part of the sensor for 5 seconds.
Power and environment. The waterproof grade is IP20, and the IP rating is stated in the data as IP20 to IP44.
Typical uses. It suits automatic lighting control by presence detection in indoor buildings equipped with a DALI line.
Integration. The product integrates into an existing DALI network and is operated with the dedicated mobile application. Available on quotation from Atlas Electronics.
The Sunricher SR-BL9032A-PIR-D is a PIR sensor controller integrated into the luminaire, linking DALI presence detection to a Bluetooth mesh network for lighting control.
SR-BL9032A-PIR-DMax. 30mA
2. Datasheet extract (recorded values)
Parameter
Value
SR-BL9032A-PIR-D
Max. 30mA
Applications and use cases
Architectures in which SR-BL9032A-PIR-D can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for SR-BL9032A-PIR-D and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.