SUP-2100 single-loop digital display controller from Supmea, used to display and control a physical quantity with alarm outputs and analog transmission.
Measurement Accuracy±0.2%FS
Graduation Number Pn — Signal type — Measure range — Graduation Number Pn — Signal typeMeasure range
ModelSUP-2100
Product overview
Supmea SUP-2100. this single-loop digital display controller is a process control device with a dual four-digit LED display. It is designed to work with various sensors and transmitters to display temperature, pressure, liquid level, speed or force.
Accuracy and display. Measurement accuracy is ±0.2%FS. The two four-digit LED displays show more information at the same time, with a function to restore factory default parameters.
Outputs and communication. The controller provides an analog output selectable among 4-20 mA, 1-5 V, 0-10 mA, 0-5 V, 0-20 mA and 0-10 V, an alarm output with upper and lower limit alarms and adjustable alarm return difference, and an RS232 printing interface for manual, timed and alarm printouts. RS-485/232 communication is mentioned in the manufacturer's introduction.
Power and environment. Power supply is AC/DC 100-240 V (50/60 Hz, consumption ≤5 W) or DC 12-36 V (consumption ≤3 W). Operating temperature ranges from -10 to 50 °C, without condensation or icing.
Mounting and format. The controller is offered in ten sizes, including 96×96, 96×48, 48×96, 72×72, 48×48, 160×80 and 80×160 mm, and installs by standard snap-in mounting.
Integration. It works with sensors and transmitters to drive a valve or heater through its alarm or analog output. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for SUP-2100, with where it comes from. Use the filters to find one quickly.
All specifications (9)
Characteristic
Value
Alarm Output
ALM----With upper and lower limit alarm function, with alarm return difference setting; Relay capacity:; AC125V/0.5A (small) DC24V/0.5A (small) (Resistive load); AC220V/2A(big) DC24V/2A(big) (Resistive load); Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Dimension
A. 160*80*110mm; B. 80*160*110mm; C. 96*96*110mm; D. 96*48*110mm; E. 48*96*110mm; F.72*72*110mm; H. 48*48*110mm; K.160*80*110mm; L. 80*160*110mm; M. 96*96*110mm
Graduation Number Pn — Signal type — Measure range — Graduation Number Pn — Signal type
Measure range
Measurement Accuracy
±0.2%FS
Model
SUP-2100
Power supply
AC/DC100~240V (Frequency 50/60Hz) Power consumption≤5W; DC 12~36V Power consumption≤3W
Printout
RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions
Transmission output
Analog output----4-20 mA, 1-5v, 0-10mA, 0-5V, 0-20mA, 0-10V
Use Environment
Operating temperature (-10~50℃) No condensation, no icing
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for SUP-2100. For a missing document or a specific revision, our experts send it to you.
SUP-2100 single-loop digital display controller from Supmea, used to display and control a physical quantity with alarm outputs and analog transmission.
Measurement Accuracy±0.2%FS
Graduation Number Pn — Signal type — Measure range — Graduation Number Pn — Signal typeMeasure range
ModelSUP-2100
2. Datasheet extract (recorded values)
Parameter
Value
Alarm Output
ALM----With upper and lower limit alarm function, with alarm return difference setting; Relay capacity:; AC125V/0.5A (small) DC24V/0.5A (small) (Resistive load); AC220V/2A(big) DC24V/2A(big) (Resistive load); Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Dimension
A. 160*80*110mm; B. 80*160*110mm; C. 96*96*110mm; D. 96*48*110mm; E. 48*96*110mm; F.72*72*110mm; H. 48*48*110mm; K.160*80*110mm; L. 80*160*110mm; M. 96*96*110mm
Graduation Number Pn — Signal type — Measure range — Graduation Number Pn — Signal type
Measure range
Measurement Accuracy
±0.2%FS
Model
SUP-2100
Power supply
AC/DC100~240V (Frequency 50/60Hz) Power consumption≤5W; DC 12~36V Power consumption≤3W
Printout
RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions
Transmission output
Analog output----4-20 mA, 1-5v, 0-10mA, 0-5V, 0-20mA, 0-10V
Use Environment
Operating temperature (-10~50℃) No condensation, no icing
Applications and use cases
Architectures in which SUP-2100 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSupmea
SUP-2100
Single-loop digital display controller with dual LED screen
Measurement Accuracy
±0.2%FS
Graduation Number Pn — Signal type — Measure range — Graduation Number Pn — Signal type
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details