01324 – Coriolis mass flowmeter with 4-20 mA and RS485 outputs

Coriolis mass flowmeter with 4-20 mA and RS485 outputs

General Industrial Sensors & Transmitters

  • (0.2~2.0)g/cm
  • ±0.0005g/cm
  • DN10~DN350
  • 220VAC; 24VDC
Manufacturer part number
01324
Manufacturer
Supmea
Measuring Range
(0.2~2.0)g/cm
Accuracy
±0.1%, ±0.15%, ±0.25%, ±0.5%

Coriolis mass flowmeter measuring mass flow, volume flow, temperature and density. It is used for process control and flow totalising in industry.

Product overview

Supmea Coriolis mass flowmeter, reference 01324 — The Supmea 01324 Coriolis mass flowmeter is an industrial instrument for mass flow measurement in process control. It measures mass flow, volume flow, temperature and density of the fluid.

Main characteristics. Accuracy of ±0.1%, ±0.15%, ±0.25% or ±0.5% depending on the version, with a density error of ±0.0005 g/cm and repeatability of ±0.0001 g/cm. The density measuring range is 0.2 to 2.0 g/cm. The nominal diameter ranges from DN10 to DN350. The working pressure is up to 4.0 MPa and the working temperature is -40 to +60 ℃.

Interfaces and communication. The flowmeter provides pulse, 4-20 mA and RS485 outputs. The MODBUS RTU communication protocol is supported, allowing integration into a supervisory system or a programmable logic controller through the RS485 port. A convenient human-machine interface simplifies configuration and reading.

Power and protection. It operates on 220 VAC or 24 VDC. The sensor has an IP67 rating and the transmitter housing an IP65 rating.

Typical uses. This flowmeter suits process control and flow totalising in the sectors named by the manufacturer, including petroleum, petrochemical, chemical, pharmaceutical, marine, municipal water, paper, food and energy. It also supports custody transfer measurement. It is used together with a BPM transmitter that provides instantaneous flow, flow totals and real-time monitoring of density and temperature.

Compensation. The flowmeter includes temperature and pressure compensation. The measuring tube has a small vibration amplitude.

See all specifications

Highlights

  • Accuracy: ±0.1%, ±0.15%, ±0.25%, ±0.5%
  • Density error: ±0.0005g/cm
  • Diameter: DN10~DN350
  • Ingress Protection: Sensor: IP67, Launcher: IP65
  • Measuring Range: (0.2~2.0)g/cm
  • Medium: Mass flow, volume flow, temperature, density

Typical applications

Derived from the part category, not a compatibility statement.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.