Supmea FLC420 volumetric turbine flowmeter measuring the flow of low-viscosity liquids in closed pipelines, from DN10 to DN200.
Flow range0.2–800 m³/h
Electrical InterfaceAviation connector, active pulse output
AccuracyLevel 0.5 / Level 1.0
Response time250ms
ConnectionsThreaded, flange or clamp
DN10(0.2-1.2)
Product overview
Overview. The Supmea FLC420 turbine flowmeter is a velocity-type instrument measuring the volumetric flow of low-viscosity liquids in closed pipelines, from DN10 to DN200 and 0.2 to 800 m³/h.
Main characteristics. Accuracy Level 0.5 or Level 1.0, repeatability equal to one third of the accuracy level, range ratio up to 10:1 (1:6 for DN10) and 250 ms response time. Design without sealing ring.
Connections. Threaded, flange or clamp connections, for medium temperatures from -20 to 80 °C with a stainless steel measuring tube.
Power and output. DC supply from 12 to 24 V, maximum consumption 0.15 W at 12 VDC and 0.5 W at 24 VDC. Active pulse output on an aviation connector, pulse width proportional to the flow rate.
Operating conditions. Ambient temperature from -20 to 60 °C, relative humidity from 5% to 90%. Medium viscosity below 5×10⁻⁶ m²/s; above this value, calibration with the actual liquid is required before use.
Typical uses. Flow monitoring of clean cooling liquids in the liquid cooling loops of data centers, and monitoring and control of small flows in pharmaceutical, chemical and food processes.
Supmea FLC420 volumetric turbine flowmeter measuring the flow of low-viscosity liquids in closed pipelines, from DN10 to DN200.
Flow range0.2–800 m³/h
Electrical InterfaceAviation connector, active pulse output
AccuracyLevel 0.5 / Level 1.0
Response time250ms
ConnectionsThreaded, flange or clamp
2. Datasheet extract (recorded values)
Parameter
Value
Response time
250ms
Accuracy
Level 0.5 / Level 1.0
Ambient conditions
Temperature: (-20 to 60) C; Relative humidity: 5%-90%
Connections
Threaded, flange or clamp
DN10
(0.2-1.2)
DN100
(20-200)
DN125
(25-250)
DN15
(0.6-6)
DN150
(30-300)
DN20
(0.8-8)
DN200
(80-800)
DN25
(1-10)
DN32
(1.5-15)
DN40
(2-20)
DN50
(4-40)
DN65
(7-70)
DN80
(10-100)
Electrical Interface
Aviation connector, active pulse output
Flow range
0.2–800 m³/h
Medium temperature
(-20 ~ 80)℃ (stainless steel measuring tube)
Medium Viscosity
less than 5×10 -6 m²/s (for liquids with a flow rate greater than 5×10 -6 m²/s, the flowmeter must be calibrated with actual liquid before use)
Nominal diameter
DN10~DN200
Output
Active pulse signal
Pipe size
DN10–DN200
Power consumption
24 VDC power supply: maximum 0.5 W; 12 VDC power supply: maximum 0.15 W
Power supply
DC: (12~24)V
Process Connection
Threaded
Range ratio
DN10: 1:6; DN15-DN200: 1:10
Repeatability
1/3 of the accuracy level
Storage conditions
Temperature: (-20 to 60) C; Relative humidity: <=85%
Transmitter output
Pulse width
Applications and use cases
Architectures in which 02293 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details