MDA_EC_CONDUCTIVITY_METER
Industrial conductivity meter with electrode, 4-20 mA and RS485 output

- Temperature range
- -10-130℃
- Measure range
- 0.01 electrode: 0-20.00us/cm
- Accuracy
- ±2%FS
- Communication
- RS485, Modbus-RTU
Industrial conductivity meter with electrode, 4-20 mA and RS485 output
The Supmea MDA-EC conductivity meter measures the electrical conductivity of liquids, with 4-20 mA output, relay and RS485 Modbus-RTU communication for process monitoring.
Overview. The Supmea MDA-EC is a conductivity controller (electrical conductivity and TDS meter) for measuring the conductivity of liquid media. It is offered in several ranges depending on the electrode used.
Main characteristics. The 0.01 electrode range covers 0-20.00 µS/cm, the 0.1 electrode range 0.2-200.0 µS/cm, the 1.0 electrode range 2-2000 µS/cm and the 10.0 electrode range 0.02-20 mS/cm. Accuracy is ±2 %FS. Temperature compensation is manual or automatic, with NTC10K or PT1000 probe.
Interfaces and connectivity. The device provides a 4-20 mA signal output (maximum loop load 750 Ω, 0.2 %FS), a 250 VAC / 3 A relay output and an RS485 link with Modbus-RTU protocol.
Power and environment. Power supply AC220V ±10 %, 50/60 Hz, or DC24V ±20 %, consumption ≥ 6 W. Measured medium temperature range -10 to 130 °C, operating temperature 0 to 60 °C, operating relative humidity 10 to 85 %RH.
Typical uses. Process measurement and conductivity control in industrial water treatment, including industrial wastewater, electroplating plants, the paper industry and the drinks industry, as indicated by the manufacturer. The RS485 Modbus-RTU connection allows integration into a PLC or supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MDA_EC_CONDUCTIVITY_METER, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±2%FS |
| Communication | RS485, Modbus-RTU |
| Measure range | 0.01 electrode: 0-20.00us/cm |
| Measuring medium | Liquid |
| Model | MDA-EC |
| Operation condition | Temperature: 15~65℃ Relative humidity: (5~95)%RH |
| Operation Temperature | 0~60℃ |
| Power supply | AC220V±10%, 50Hz/60Hz DC24V±20%, ≥6W |
| Relative humidity | (10~85)%RH |
| Relay Output | 250VAC, 3A |
| Signal Output | 4-20mA, maximum loop 750Ω, 0.2%FS |
| Temp. compensation | NTC10K/PT1000 Manual/ Auto temperature compensation |
| Temperature range | -10-130℃ |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MDA_EC_CONDUCTIVITY_METER. For a missing document or a specific revision, our experts send it to you.
The Supmea MDA-EC conductivity meter measures the electrical conductivity of liquids, with 4-20 mA output, relay and RS485 Modbus-RTU communication for process monitoring.
| Parameter | Value |
|---|---|
| Accuracy | ±2%FS |
| Communication | RS485, Modbus-RTU |
| Measure range | 0.01 electrode: 0-20.00us/cm |
| Measuring medium | Liquid |
| Model | MDA-EC |
| Operation condition | Temperature: 15~65℃ Relative humidity: (5~95)%RH |
| Operation Temperature | 0~60℃ |
| Power supply | AC220V±10%, 50Hz/60Hz DC24V±20%, ≥6W |
| Relative humidity | (10~85)%RH |
| Relay Output | 250VAC, 3A |
| Signal Output | 4-20mA, maximum loop 750Ω, 0.2%FS |
| Temp. compensation | NTC10K/PT1000 Manual/ Auto temperature compensation |
| Temperature range | -10-130℃ |
Answers to the questions that the recorded characteristics of MDA_EC_CONDUCTIVITY_METER can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": RS485, Modbus-RTU.
Yes — recorded under "Communication": RS485, Modbus-RTU.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Industrial conductivity meter with electrode, 4-20 mA and RS485 output

SUP-ADE3500 Inductive conductivity electrode

SUP-ADE3300 Conductivity Sensor for Pure Water and Water Treatment

TDS 7001G Conductivity sensor for data center

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MDA_EC_CONDUCTIVITY_METER |
| Manufacturer | Supmea |
Conductivity Sensors
Industrial Inductive Conductivity and TDS Sensor
Price on request
Conductivity Sensors
RS485 Modbus RTU IP68 Water Conductivity EC Sensor
Price on request
Conductivity Sensors
Industrial RS485 Water Electrical Conductivity Sensor IP68 · Ref. : SEN0707
Price on request
Conductivity Sensors
Online water conductivity controller with 4-20 mA outputs
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details