FW511
Photoelectric 2-Wire Smoke Detector

- Operating Temperature
- 32°F to 120°F (0°C to 49°C)
- Sensitivity Range
- 1.5% - 4.0% per ft obscuration
- Alarm Current
- 50mA @ 24VDC
- Standby Current
- 35μA @ 24VDC
Photoelectric 2-Wire Smoke Detector
The Tongfang BMS FW511 is a photoelectric smoke detector for conventional fire alarm systems, UL 268 listed and compliant with NFPA 72.
FW511 smoke detector. The Tongfang BMS FW511 is a photoelectric smoke detector designed for fire detection in conventional fire alarm systems. Main characteristics — Photoelectric optical detection, automatic drift compensation of ±0.5% per year and a sensitivity range of 1.5% to 4.0% obscuration per foot. The housing measures 5.5 in (140 mm) in diameter by 1.8 in (46 mm) high and weighs 6.2 oz (176 g). Connectivity and wiring — 2-wire configuration carrying both power and signal, with a red alarm LED visible over 360°. Power and environment — Operating voltage of 12 to 30 VDC, alarm current of 50 mA at 24 VDC and standby current of 35 μA at 24 VDC. Operating temperature of 32 °F to 120 °F (0 °C to 49 °C) and relative humidity of 10% to 93% non-condensing. Typical uses — Ceiling or wall mounting for early detection of smoldering fires, in installations meeting the NFPA 72 requirements. Integration — Maximum spacing of 30 ft (9 m) between detectors on a standard ceiling, minimum distance of 3 ft (1 m) from air vents, and NFPA 72 Table 17.6.3.5.1 applies on sloped ceilings. Above 10 ft (3 m) ceiling height, manufacturer engineering is required. Certifications — UL 268, UL 217, CSFM and FM. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for FW511, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Alarm Current | 50mA @ 24VDC |
| Alarm indication | Red LED (360° visible) |
| Annual — Cleaning & sensitivity test | Clean optical chamber, verify sensitivity |
| Application — Spacing — Distance from Walls | Distance from Air Vents |
| Certification | UL 268, UL 217, CSFM, FM |
| Color | White (Standard), Ivory, Gray available |
| Detection Type | Photoelectric (Optical) |
| Dimensions (Diameter x Height) | 5.5" x 1.8" (140mm x 46mm) |
| Drift Compensation | Automatic, ±0.5% per year |
| Frequency — Activity | Purpose |
| High Ceiling (>10') — Engineering required | Consult manufacturer |
| Model Number | FW511 |
| Monthly — Visual inspection | Check for physical damage or obstructions |
| Mounting | Ceiling or Wall Mount |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Operating Voltage | 12-30VDC |
| Product Name | Standard Smoke Detector |
| Quarterly — Functional test | Verify detector operation using test tool |
| Relative humidity | 10% to 93% RH (Non-condensing) |
| Sensitivity Range | 1.5% - 4.0% per ft obscuration |
| Sloped Ceiling — Follow NFPA 72 Table 17.6.3.5.1 — 4" (10cm) minimum | 3' (1m) minimum |
| Standard Ceiling (≤10') — 30' (9m) between detectors — 4" (10cm) minimum | 3' (1m) minimum |
| Standby Current | 35μA @ 24VDC |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
| System Compatibility | Conventional Fire Alarm Systems |
| Test Method | Magnetic Test / Functional Test |
| Weight | 6.2 oz (176g) |
| Wiring Configuration | 2-Wire (Power & Signal) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for FW511. For a missing document or a specific revision, our experts send it to you.
The Tongfang BMS FW511 is a photoelectric smoke detector for conventional fire alarm systems, UL 268 listed and compliant with NFPA 72.
| Parameter | Value |
|---|---|
| Alarm Current | 50mA @ 24VDC |
| Alarm indication | Red LED (360° visible) |
| Annual — Cleaning & sensitivity test | Clean optical chamber, verify sensitivity |
| Application — Spacing — Distance from Walls | Distance from Air Vents |
| Certification | UL 268, UL 217, CSFM, FM |
| Color | White (Standard), Ivory, Gray available |
| Detection Type | Photoelectric (Optical) |
| Dimensions (Diameter x Height) | 5.5" x 1.8" (140mm x 46mm) |
| Drift Compensation | Automatic, ±0.5% per year |
| Frequency — Activity | Purpose |
| High Ceiling (>10') — Engineering required | Consult manufacturer |
| Model Number | FW511 |
| Monthly — Visual inspection | Check for physical damage or obstructions |
| Mounting | Ceiling or Wall Mount |
| Operating Temperature | 32°F to 120°F (0°C to 49°C) |
| Operating Voltage | 12-30VDC |
| Product Name | Standard Smoke Detector |
| Quarterly — Functional test | Verify detector operation using test tool |
| Relative humidity | 10% to 93% RH (Non-condensing) |
| Sensitivity Range | 1.5% - 4.0% per ft obscuration |
| Sloped Ceiling — Follow NFPA 72 Table 17.6.3.5.1 — 4" (10cm) minimum | 3' (1m) minimum |
| Standard Ceiling (≤10') — 30' (9m) between detectors — 4" (10cm) minimum | 3' (1m) minimum |
| Standby Current | 35μA @ 24VDC |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
| System Compatibility | Conventional Fire Alarm Systems |
| Test Method | Magnetic Test / Functional Test |
| Weight | 6.2 oz (176g) |
| Wiring Configuration | 2-Wire (Power & Signal) |
Points to check before using FW511 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Alarm Current | 50mA @ 24VDC |
| Operating Voltage | 12-30VDC |
| Standby Current | 35μA @ 24VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of FW511 can answer. A question is not asked when nothing is recorded to answer it.
32°F to 120°F (0°C to 49°C) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Photoelectric 2-Wire Smoke Detector

Standard Heat Detector

Conventional Heat Detector

Smart Liquid Solid Radar Level Meter Dust Smoke Environment

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | FW511 |
| Manufacturer | Tongfang BMS |
Smoke and Flame Detectors
Electro-optical UV and infrared wide-angle flame detector
Price on request
Smoke and Flame Detectors
Intelligent Event Detection Server for Traffic, 32 Channels · Ref. : IVS-TB9000-4K-TS2
Price on request
Smoke and Flame Detectors
Zigbee smoke detector with 85 dB audible alarm · Ref. : SD324
Price on request
Smoke and Flame Detectors
Zigbee 3.0 ceiling-mount smoke detector
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details