The Ubiquiti EAH-8 is an enterprise access control hub managing up to eight doors for entry and exit control, with battery backup power support.
Ambient Operating Temperature0 to 40° C (32 to 104° F)
Networking Interface(10) 10/100/1000 Base-T
Max Power Consumption240W
Dimensions379 x 355 x 105 mm (15 x 14 x 4.1")
MountingWall
Ambient Operating Humidity5 to 95% noncondensing
Product overview
Ubiquiti EAH-8 access controller. The Ubiquiti EAH-8 is an Enterprise Access Hub, an access control hub designed to control entry and exit on eight doors, with a capacity of 10,000 users.
Main characteristics. The product provides eight inputs for request-to-exit devices, eight inputs for door position sensors and one emergency input, along with a factory reset button. Its SGCC steel housing with polycarbonate cover is intended for wall mounting, indoor use only.
Interfaces and connectivity. The EAH-8 features ten 10/100/1000 Base-T networking ports and eight PoE+ outputs of 30 W per port, with a maximum aggregated 190 W. It has eight lock terminals (12V or dry) and four AUX terminals for advanced setup (chime, siren, door opener). A powered output relay provides 12V DC, 1A for the lock.
Power and environment. Universal input 100 to 240V AC, 50/60 Hz, with a 32 to 48V DC input for lead acid battery. Maximum power consumption is 240W. Operating temperature 0 to 40° C and humidity 5 to 95% noncondensing.
Typical uses. Access management in enterprise buildings with control of doors, exit requests and door position sensors, with maximum cable lengths depending on the lock type and conductor gauge.
Integration. PoE cabling should be at least Category 5e. The product is certified CE, FCC, IC, UL 294 and CAN/ULC-60839-11-1, grade I. Available on quotation from Atlas Electronics.
Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
PoE Interface
(8) PoE+ outputs, 50V DC, 30W per port (Max 190W aggregated)
Power Method
Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
Power supply
AC/DC, internal
Powered Output Relay
Lock: 12V DC, 1A/ Dry Aux: Dry only
Recommend Max. Cable Length — Other locks
(1A)
24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
Software information
The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Supported Doors
8
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Weight
Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
No specification matches.
Last verification : 2026-11-05
Technical documentation
Official documents and the technical data recorded for EAH-8. For a missing document or a specific revision, our experts send it to you.
Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
PoE Interface
(8) PoE+ outputs, 50V DC, 30W per port (Max 190W aggregated)
Power Method
Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
Power supply
AC/DC, internal
Powered Output Relay
Lock: 12V DC, 1A/ Dry Aux: Dry only
Recommend Max. Cable Length — Other locks
(1A)
24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
Software information
The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Supported Doors
8
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Weight
Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Integration
Points to check before using EAH-8 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 to 40° C (32 to 104° F) — check it against the installation environment.
Power and communication
Max Power Consumption
240W
Power Method
Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
Power supply
AC/DC, internal
Powered Output Relay
Lock: 12V DC, 1A/ Dry Aux: Dry only
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 to 40° C (32 to 104° F) — check it against the installation environment.
Applications and use cases
Architectures in which EAH-8 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Badges are lent and lost, and attendance is noted by hand. Face or fingerprint terminals, access controllers, door stations and locks control who enters and record working time
To check
Number of users and doors
Data protection rules for biometric data
Link with the payroll or HR software
Associated system blocks
TerminalsControllers and locksDoor stations
Need a complete solution?
Send a request for EAH-8 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1Certifications
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level IUL 294 Level
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.UL 294 Statement
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details