Ubiquiti 5-inch viewer screen for intercom and access reader, PoE powered, designed for visitor screening and remote access control indoors.
Ambient Operating Temperature0 to 40° C (32 to 104° F)
Supported Voltage Range44–57V DC
Networking Interface(1) 10/100 Mbps RJ45 port
Max Power Consumption5W
Dimensions135 x 72 x 31.8 mm (5.3 x 2.8 x 1.3")
Ambient Operating Humidity5 to 95% noncondensing
Product overview
Overview. The UA-INTERCOM-VIEWER from Ubiquiti is a viewer screen for video intercom systems, designed to work with the Intercom and Reader Pro for visitor screening and remote access control. It is listed under intercoms and video door stations.
Main characteristics. The 127 mm (5 inch) diagonal screen shows a 1280 x 720 px resolution in portrait orientation, with a typical luminance of 300 nits. The glass and polycarbonate enclosure weighs 168 g. Dimensions are 135 x 72 x 31.8 mm. The product is for indoor use only.
Interfaces and connectivity. One 10/100 Mbps RJ45 Ethernet port provides network connection, and a factory reset button is included. The product has a CAN bus and is rated grade I under CAN/ULC-60839-11-1.
Power and environment. The viewer is powered over PoE, under UL 294 with a power-limited Class 2 supply, across a 44 to 57 V DC range, with a maximum consumption of 5 W. It operates between 0 and 40 °C, at 5 to 95 % humidity, non-condensing. Cat 5e cabling is the recommended minimum.
Security and compliance. The UL 294 level is I for destructive attack, line security, endurance and standby power. The product is certified CE, FCC, IC, UL 294 and CAN/ULC-60839-11-1.
Installation. Wall mounting is included, and a gang box mount is optional. Management is done through the Access application, whose software version can be checked on the Ubiquiti website.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for UA-INTERCOM-VIEWER, with where it comes from. Use the filters to find one quickly.
All specifications (26)
Characteristic
Value
Dimensions
135 x 72 x 31.8 mm (5.3 x 2.8 x 1.3")
Ambient Operating Humidity
5 to 95% noncondensing
Ambient Operating Temperature
0 to 40° C (32 to 104° F)
Buttons
(1) Factory reset
CAN/ULC-60839-11-1 Grade
Grade assignment: I
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Connectivity
Ethernet
Display — Luminance
300 nits (Typical)
Display Resolution
1280 x 720 px
Display — Screen Orientation
Portrait
Display size
127 mm (5") diagonal
Document number, and issue date and/or revision level
UA-Intercom-Viewer, V01
Enclosure Material
Glass, polycarbonate
Indoor and Outdoor Use
Indoor only
Management Application
Access
Max Power Consumption
5W
Mount Material
Aluminum alloy
Mounting
Wall (Included) Gang box mount (Optional)
Networking Interface
(1) 10/100 Mbps RJ45 port
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
Power Method
PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Software information
The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Supported Voltage Range
44–57V DC
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Weight
168 g (5.9 oz)
No specification matches.
Last verification : 2026-11-05
Technical documentation
Official documents and the technical data recorded for UA-INTERCOM-VIEWER. For a missing document or a specific revision, our experts send it to you.
Ubiquiti 5-inch viewer screen for intercom and access reader, PoE powered, designed for visitor screening and remote access control indoors.
Ambient Operating Temperature0 to 40° C (32 to 104° F)
Supported Voltage Range44–57V DC
Networking Interface(1) 10/100 Mbps RJ45 port
Max Power Consumption5W
Dimensions135 x 72 x 31.8 mm (5.3 x 2.8 x 1.3")
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
135 x 72 x 31.8 mm (5.3 x 2.8 x 1.3")
Ambient Operating Humidity
5 to 95% noncondensing
Ambient Operating Temperature
0 to 40° C (32 to 104° F)
Buttons
(1) Factory reset
CAN/ULC-60839-11-1 Grade
Grade assignment: I
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Connectivity
Ethernet
Display — Luminance
300 nits (Typical)
Display Resolution
1280 x 720 px
Display — Screen Orientation
Portrait
Display size
127 mm (5") diagonal
Document number, and issue date and/or revision level
UA-Intercom-Viewer, V01
Enclosure Material
Glass, polycarbonate
Indoor and Outdoor Use
Indoor only
Management Application
Access
Max Power Consumption
5W
Mount Material
Aluminum alloy
Mounting
Wall (Included) Gang box mount (Optional)
Networking Interface
(1) 10/100 Mbps RJ45 port
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
Power Method
PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Software information
The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Supported Voltage Range
44–57V DC
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Weight
168 g (5.9 oz)
Integration
Points to check before using UA-INTERCOM-VIEWER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 to 40° C (32 to 104° F) — check it against the installation environment.
Power and communication
Max Power Consumption
5W
Power Method
PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Supported Voltage Range
44–57V DC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 to 40° C (32 to 104° F) — check it against the installation environment.
Applications and use cases
Architectures in which UA-INTERCOM-VIEWER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Badges are lent and lost, and attendance is noted by hand. Face or fingerprint terminals, access controllers, door stations and locks control who enters and record working time
Announcements across a site need wiring that is hard to extend. IP speakers and paging systems use the data network, with intercoms and IP phones for calls
To check
Zones and sound level needed in each area
Power over Ethernet budget of the switches
Integration with the telephone system over SIP
Associated system blocks
Paging and speakersIntercoms and phones
Need a complete solution?
Send a request for UA-INTERCOM-VIEWER and the other parts of your project.
Answers to the questions that the recorded characteristics of UA-INTERCOM-VIEWER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support CAN bus?
Yes — recorded under "CAN/ULC-60839-11-1 Grade": Grade assignment: I.
2Does it have an Ethernet port?
Yes — recorded under "Connectivity": Ethernet.
3What is the operating temperature range?
0 to 40° C (32 to 104° F) (source: Ambient Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Device: -30 to 60° C (-22 to 140° F) Display: -25 to 60° C (-13 to 140° F) (The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v 1.0.66))
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1Certifications
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level IUL 294 Level
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.UL 294 Statement
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details