UPS-TOWER-US
Line interactive tower UPS 1000 VA with backup outlets

- Ambient Operating Temperature
- 0 to 40° C (32 to 104° F)
- Input voltage range
- 89–145V AC
- Nominal Input Voltage
- 120V AC
- Output short circuit current
- Ipeak 334.8A Irms 68.2A
Line interactive tower UPS 1000 VA with backup outlets
Tower-format line interactive UPS rated 1000VA/600W from Ubiquiti, designed to provide backup power and surge protection for network and IT equipment connected on 120V AC.
Overview. The Ubiquiti UPS-TOWER-US is a tower-format line interactive UPS rated 1,000 VA / 600 W, designed to supply backup power to a set of equipment connected on a 120V AC installation.
Main characteristics. It contains a 12V 9Ah lead acid battery and provides a 120V AC output with ±10% voltage regulation in battery mode. Transfer time is 6 ms typical and 10 ms maximum in battery mode, with a simulated sine wave output. Runtime is 2 minutes at full load and 7 minutes at half load, and recharging takes 6 to 8 hours to reach 90% capacity.
Interfaces and connectivity. The unit has one 100/10 MbE port for network connection and GbE ports for surge in and surge out. It is managed over Ethernet. It includes an OVC II AC input with a 1.8 m NEMA 5-15P non-removable power cord, 5 NEMA 5-15R outlets with battery backup and surge protection, and 5 NEMA 5-15R outlets with surge protection only. Outlets are not individually resettable.
Power and environment. The input voltage range is 89 to 145V AC, with a frequency of 50/60 Hz ±5 Hz in AC mode and 60 Hz ±1 Hz in battery mode. Operating temperature is 0 to 40 °C and humidity 0 to 95% noncondensing, up to an operating altitude of 3,000 m. The IP rating is IP20 to IP44 according to the data.
Compliance. The UPS is certified FCC, IC, UL 1778 and CSA C22.2 No. 107.3.
Integration. The data indicate compatibility with Graceful Shutdown for UNVR and UNAS devices and NUT compatibility for third-party devices, allowing a controlled shutdown of connected equipment during an outage.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UPS-TOWER-US, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | 288 x 99 x 280.5 mm (11.3 x 3.9 x 11") |
| Form factor | Desktop |
| Output voltage | 120V AC |
| AC Voltage Regulation | ±10% (Battery mode) |
| Ambient Operating Humidity | 0 to 95% noncondensing |
| Ambient Operating Temperature | 0 to 40° C (32 to 104° F) |
| Ambient Storage Temperature | -20 to 50° C (-4 to 122° F) |
| Battery Charging Time | 6-8 hours recovery to 90% capacity |
| Battery Type | (1) Lead Acid 12V, 9Ah |
| Buttons | (1) Power (1) Factory reset |
| Capacity | 1,000VA/600W |
| Certifications | FCC, IC, UL 1778, CSA C22.2 No. 107.3 |
| Enclosure Material | Polycarbonate and acrylonitrile butadiene styrene blend |
| Frequency Range | AC mode: 50/60 Hz ±5 Hz (Auto sensing) Battery mode: 60 Hz ±1 Hz |
| Input voltage range | 89–145V AC |
| LEDs — Battery Indicator | All off: 0% (1) Steady blue: battery 1–19% (2) Steady blue: battery 20–39% (3) Steady blue: battery 40–59% (4) Steady blue: battery 60–79% (5) Steady blue: battery 80–100% |
| LEDs — Status | Off: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery |
| Management | Ethernet |
| Networking Interface | (1) 100/10 MbE port for network connection (2) GbE ports for surge in/out |
| Nominal Input Voltage | 120V AC |
| Operating Altitude | 3,000 m (1.9 mi) |
| Operating Environment | Pollution Degree 2 |
| Output short circuit current | Ipeak 334.8A Irms 68.2A |
| Overload at Battery Mode | 110% shutdown in 5 sec 120% shutdown immediately |
| Overload at On-Line Mode | 110% 5 min go to fault 120% go to fault immediately |
| Power | (1) OVC II AC in: NEMA 5‑15P, 1.8 m (5.9 ft) non-removable power cord (5) Battery backup/surge protection: NEMA 5‑15R (5) Surge protection: NEMA 5‑15R (Outlets are not individually resettable) |
| Power Method | (1) TN system, 120V AC, 12A Max., 50/60 Hz |
| Runtime | Full load: 2 min Half load: 7 min |
| Short Circuit Protection at On-Line Mode | Breaker, 250V AC, 15A |
| Transfer Time | 6 ms typical; 10 ms max. (Battery mode) |
| Type | Line interactive |
| Wave Form | Simulated sine wave (Battery mode) |
| Weatherproofing | IP20 |
| Weight | 8.17 kg (18 lb) |
No specification matches.
Last verification : 2026-11-05
Official documents and the technical data recorded for UPS-TOWER-US. For a missing document or a specific revision, our experts send it to you.
Tower-format line interactive UPS rated 1000VA/600W from Ubiquiti, designed to provide backup power and surge protection for network and IT equipment connected on 120V AC.
| Parameter | Value |
|---|---|
| Dimensions | 288 x 99 x 280.5 mm (11.3 x 3.9 x 11") |
| Form factor | Desktop |
| Output voltage | 120V AC |
| AC Voltage Regulation | ±10% (Battery mode) |
| Ambient Operating Humidity | 0 to 95% noncondensing |
| Ambient Operating Temperature | 0 to 40° C (32 to 104° F) |
| Ambient Storage Temperature | -20 to 50° C (-4 to 122° F) |
| Battery Charging Time | 6-8 hours recovery to 90% capacity |
| Battery Type | (1) Lead Acid 12V, 9Ah |
| Buttons | (1) Power (1) Factory reset |
| Capacity | 1,000VA/600W |
| Certifications | FCC, IC, UL 1778, CSA C22.2 No. 107.3 |
| Enclosure Material | Polycarbonate and acrylonitrile butadiene styrene blend |
| Frequency Range | AC mode: 50/60 Hz ±5 Hz (Auto sensing) Battery mode: 60 Hz ±1 Hz |
| Input voltage range | 89–145V AC |
| LEDs — Battery Indicator | All off: 0% (1) Steady blue: battery 1–19% (2) Steady blue: battery 20–39% (3) Steady blue: battery 40–59% (4) Steady blue: battery 60–79% (5) Steady blue: battery 80–100% |
| LEDs — Status | Off: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery |
| Management | Ethernet |
| Networking Interface | (1) 100/10 MbE port for network connection (2) GbE ports for surge in/out |
| Nominal Input Voltage | 120V AC |
| Operating Altitude | 3,000 m (1.9 mi) |
| Operating Environment | Pollution Degree 2 |
| Output short circuit current | Ipeak 334.8A Irms 68.2A |
| Overload at Battery Mode | 110% shutdown in 5 sec 120% shutdown immediately |
| Overload at On-Line Mode | 110% 5 min go to fault 120% go to fault immediately |
| Power | (1) OVC II AC in: NEMA 5‑15P, 1.8 m (5.9 ft) non-removable power cord (5) Battery backup/surge protection: NEMA 5‑15R (5) Surge protection: NEMA 5‑15R (Outlets are not individually resettable) |
| Power Method | (1) TN system, 120V AC, 12A Max., 50/60 Hz |
| Runtime | Full load: 2 min Half load: 7 min |
| Short Circuit Protection at On-Line Mode | Breaker, 250V AC, 15A |
| Transfer Time | 6 ms typical; 10 ms max. (Battery mode) |
| Type | Line interactive |
| Wave Form | Simulated sine wave (Battery mode) |
| Weatherproofing | IP20 |
| Weight | 8.17 kg (18 lb) |
Points to check before using UPS-TOWER-US in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Output voltage | 120V AC |
| AC Voltage Regulation | ±10% (Battery mode) |
| Battery Charging Time | 6-8 hours recovery to 90% capacity |
| Battery Type | (1) Lead Acid 12V, 9Ah |
| Input voltage range | 89–145V AC |
| LEDs — Battery Indicator | All off: 0% (1) Steady blue: battery 1–19% (2) Steady blue: battery 20–39% (3) Steady blue: battery 40–59% (4) Steady blue: battery 60–79% (5) Steady blue: battery 80–100% |
| Nominal Input Voltage | 120V AC |
| Output short circuit current | Ipeak 334.8A Irms 68.2A |
| Overload at Battery Mode | 110% shutdown in 5 sec 120% shutdown immediately |
| Power | (1) OVC II AC in: NEMA 5‑15P, 1.8 m (5.9 ft) non-removable power cord (5) Battery backup/surge protection: NEMA 5‑15R (5) Surge protection: NEMA 5‑15R (Outlets are not individually resettable) |
| Power Method | (1) TN system, 120V AC, 12A Max., 50/60 Hz |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of UPS-TOWER-US can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Management": Ethernet.
0 to 40° C (32 to 104° F) (source: Ambient Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Line interactive tower UPS 1000 VA with backup outlets

UPS 2U

UPS 2U Pro

Geekworm X-UPS1 12V/5V Dual Output Universal SBC Stackable UPS Shield

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UPS-TOWER-US |
| Manufacturer | Ubiquiti |
Industrial UPS
12 V supercapacitor UPS module for safe shutdown
Price on request
Industrial UPS
LED lighting surge protector, 15 kA max., 10 kA nominal · Ref. : PU-20KX10KTXX
Price on request
Industrial UPS
Industrial Raspberry Pi CM4/CM5 controller with X2 expansion slots · Ref. : 1012051
Price on request
Industrial UPS
8-port Gigabit PoE industrial switch with built-in UPS
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details