Wireless UNI-T tester for quick on-site testing of current transformers in metering installations, measuring primary current, secondary current and turns ratio.
Primary current0.0A~3000A (0.1A; ±1%FS)
Secondary current0.00mA~5A (0.01mA; ±0.5%FS)
Secondary current clamp connection wire length2M
Secondary low voltage; current clampJaw size: φ8mm; Dimension: 137×40×19.5mm
Data storage3000 groups
Auto Power OffYES (Around 15 minutes)
Product overview
Overview. The UNI-T UT225A/UT225B high and low voltage transformer turns ratio tester enables quick on-site testing of current transformers in metering installations. It measures primary current, secondary current and turns ratio, and identifies phase type and polarity.
Main characteristics. The turns ratio measurement range is 1 to 500. Primary current ranges from 0.0 A to 3000 A (0.1 A; ±1%FS) and secondary current from 0.00 mA to 5 A (0.01 mA; ±0.5%FS). The sampling rate is 3 times per second. The instrument stores 3000 groups of data, provides data retention and data review, and shows an overflow indication (OL symbol).
Interfaces and connectivity. The primary current clamp transmits wirelessly over a distance of 100 m. The secondary low voltage current clamp connects to the meter by a 2 m cable.
Power and environment. The instrument runs on 4 AAA 1.5 V batteries with a working time of 30 hours. It powers off automatically after around 15 minutes. The insulation rod withstands 3700 Vrms. The meter weighs 800 g without the clamps.
Typical uses. The UT225A model suits measurements on 380 V/220 V power systems, for example in residential installations. The UT225B model covers measurements up to 35 kV and is used in substations, power plants, power inspection departments, industrial and mining enterprises, inspection stations and electrical repair workshops.
Wireless UNI-T tester for quick on-site testing of current transformers in metering installations, measuring primary current, secondary current and turns ratio.
Primary current0.0A~3000A (0.1A; ±1%FS)
Secondary current0.00mA~5A (0.01mA; ±0.5%FS)
Secondary current clamp connection wire length2M
Secondary low voltage; current clampJaw size: φ8mm; Dimension: 137×40×19.5mm
Data storage3000 groups
2. Datasheet extract (recorded values)
Parameter
Value
Accessories
Tester,; Primary current transformer(CT1),; Secondary current transformer(CT2),; Tool bag,; Strap,; Battery(AAA 1.5V * 4pcs; 6F22 9V *1),; User manual
Auto Power Off
YES (Around 15 minutes)
Data Retention
YES
Data review
YES
Data storage
3000 groups
Dimension (main meter)
78mm×165mm×42mm
General Characteristics
General Characteristics
Instrument weight
800g (meter only)
Insulation rod withstand voltage
3700Vrms
No signal indication
YES
Online measurement voltage
380V/220V power system
Overflow display
YES (OL symbol display)
Power supply
1.5V AAA×4; Works time: 30 hours
Primary current
0.0A~3000A (0.1A; ±1%FS)
Primary high voltage; current clamp
Jaw size: φ200mm; Dimension: 200×370×40mm
Sampling Rate
3 times/second
Secondary current
0.00mA~5A (0.01mA; ±0.5%FS)
Secondary current clamp connection wire length
2M
Secondary low voltage; current clamp
Jaw size: φ8mm; Dimension: 137×40×19.5mm
Turn ratio measurement
1~500
UT225A
380V/220V
UT225B
up to 35KV
Wireless transmission distance
100m (Primary current clamp)
Applications and use cases
Architectures in which UT225A/UT225B can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Associated system blocks
Energy metersCurrent sensorsData collection
Need a complete solution?
Send a request for UT225A/UT225B and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productUNI-T
UT225A/UT225B
Wireless high and low voltage transformer turns ratio tester