Overview. The USR-LG210 Edge LoRa Gateway from USR IoT is an industrial gateway designed for long-distance LoRa wireless transmission, remote I/O monitoring and edge data acquisition. It links LoRa nodes to a server, cloud platform or control centre via Ethernet, RS232 or RS485.
Main characteristics. Transmission up to 8 km, with relay transmission. The SX1262 radio chip operates in the 860 MHz to 930 MHz band, with a transmit power of 12 to 30 dBm and two channels. The edge acquisition function supports up to 300 data points with JSON reporting.
Interfaces and connectivity. One RJ45 Ethernet port (10/100) and one RS232/RS485 serial port (only one usable at a time). TCP and MQTT protocols are supported, with SSL 1.0/1.2 encryption. Serial baud rates range from 2400 bps to 230400 bps. Configuration is possible by PC software, serial AT commands or network AT commands.
Power and environment. DC power supply from 9 to 36 V, via a 5.5 × 2.1 mm jack or a 2-pin 5.08 mm terminal block. Maximum current of 0.75 A at 12 V. Operating temperature from -40 °C to +85 °C and humidity from 5% to 95% RH, non-condensing. CE and RoHS compliant, ESD protection to IEC 61000-4-2 (contact 8 kV, air 15 kV). DIN rail or wall mounting.
Typical uses. Modbus TCP/RTU conversion for connecting Modbus equipment to supervision systems. Remote I/O control when combined with the LG207 node. Applications cited by the manufacturer: smart agriculture, warehouse monitoring, building energy management, smart metering and fire protection.
Industrial USR-LG210 LoRa gateway for long-range wireless transmission, remote I/O monitoring and edge data acquisition, up to 8 km.
Operating Temperature-40℃ ~ +85℃
Working currentMax: 0.75A@12V (Standard 12V/1A)
Frequency860M~930M Hz
Storage humidity1%~95%RH (Non-condensing)
Storage Temperature-40℃ ~ +125℃
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
108* 134 * 17.5 mm(Including terminal block and DIN rail kit)
Baud rate
2400bps~230400bps
Casing material
Metal & plasic casing
Channel
2 * Channel
Communication Protocol
TCP, MQTT
Config
PC software, serial AT command, network AT command
Edge Computing
Edge data acquisition, supports 300 data points, JSON reporting
Edge function
Edge acquisition, edge computing, up to 300 data points
EMC Protection
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
Encryption
SSL 1.0/1.2
Ethernet Port
1 * RJ45 connector, 10/100 compatible,
Frequency
860M~930M Hz
High-Power Transmission
Wireless transmission up to 8KM
Indicators
PWR, Work, LoRa1, LoRa2
Installation
DIN rail mounting, wall mounting
Long Coverage
Up to 8KM, relay transmission
Modbus Gateway
Modbus TCP/RTU conversion
NO
1*RS232/RS485
Operating Humidity
5%~95%RH (Non-condensing)
Operating Temperature
-40℃ ~ +85℃
Power supply
DC: 9-36V, standard 5.5*2.1 power jack, or 2-PIN 5.08mm ternimal blocks
Protocol Conversion
Modbus TCP/RTU conversion
Radio chip
SX1262
Regulatory
CE, RoHS
Reload Button
Press and hold for 4~15 to reset to factory settings
Remote IO Control
Working with LG207 can achieve remote I/O control
Serial Ports
RS232/RS485
Set button
Set botton: reserved
Signal
RS232: Tx, Rx,G(public), DB9 female connector; RS485: A, B,G(public), 3-PIN terminal block; Note: RS232 and RS485 can't use simultaneously.
Storage humidity
1%~95%RH (Non-condensing)
Storage Temperature
-40℃ ~ +125℃
Transmit Power
12 ~ 30 dBm
Working current
Max: 0.75A@12V (Standard 12V/1A)
Integration
Points to check before using LORA-GATEWAY in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40℃ ~ +85℃ — check it against the installation environment.
Power and communication
High-Power Transmission
Wireless transmission up to 8KM
Power supply
DC: 9-36V, standard 5.5*2.1 power jack, or 2-PIN 5.08mm ternimal blocks
Transmit Power
12 ~ 30 dBm
Working current
Max: 0.75A@12V (Standard 12V/1A)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40℃ ~ +85℃ — check it against the installation environment.
Applications and use cases
Architectures in which LORA-GATEWAY can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for LORA-GATEWAY and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productUSR IoT
LORA-GATEWAY
Edge LoRa gateway with data acquisition and I/O control
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details