Winsen F1012 micro thermal gas flow sensor for mass gas measurement and control in a flow channel. The manufacturer reports this product as discontinued.
Detection range50、100、200、500、1000、2000sccm
Measuring Range50、100、200、500、1000、2000sccm②
Storage Temp-40
Detection PrinciplePrinciples of thermodynamics
Full Scale Output4.90
ModelF1012
Product overview
Overview. The Winsen F1012 micro thermal gas flow sensor measures the mass flow of gas in a flow channel. It operates on the thermodynamic principle and provides a linear analog voltage output.
Main characteristics. The sensor offers high accuracy, quick response and good repeatability. It is available in several measuring ranges: 50, 100, 200, 500, 1000 and 2000 sccm, with measuring ranges within 50 to 2000 sccm also available. SCCM means standard cubic centimeter per minute, with standard conditions of 0 °C and 101.325 kPa. The full scale output is 4.90, the zero output 0.96 and the working voltage 7.0.
Compensation and calibration. A built-in temperature sensor provides professional temperature compensation. The sensor is calibrated and temperature compensated over the range of 0 to 50 °C.
Environmental conditions. The working temperature is -25 °C and the storage temperature -40 °C. Tests are performed at room temperature in clean air.
Typical uses. The F1012 suits industrial process control, air and environmental monitoring, portable detectors and meters, gas analyzers and gas chromatography.
End of life. The manufacturer states that this product has been discontinued and refers to the FRn03H flow sensor.
Winsen F1012 micro thermal gas flow sensor for mass gas measurement and control in a flow channel. The manufacturer reports this product as discontinued.
Detection range50、100、200、500、1000、2000sccm
Measuring Range50、100、200、500、1000、2000sccm②
Storage Temp-40
Detection PrinciplePrinciples of thermodynamics
Full Scale Output4.90
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
High accuracy, quick response, good repeatability
Detection Principle
Principles of thermodynamics
Detection range
50、100、200、500、1000、2000sccm
Full Scale Output
4.90
Measuring Range
50、100、200、500、1000、2000sccm②
Model
F1012
Notes
This product has been discontinued and find more FRn03H Flow Sensor
Storage Temp
-40
Target
Mass gas measurement and control in the flow channel
Working Temp
-25
Working voltage
7.0
Zero Output
0.96
Applications and use cases
Architectures in which F1012 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productWinsen
F1012
Micro thermal gas flow sensor with analog voltage output
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details