Constant potential electrolysis sensor for ethylene oxide (ETO) gas, designed for detection in petroleum and petrochemical, pharmaceutical and environmental protection applications.
Temperature range-20℃~50℃
Pressure rangeStandard atmospheric pressure±10%
Humidity range15%~90% RH (No condensation)
Detection range0-20ppm, Max 100ppm
Max Range100ppm
Bias voltage300mV
Product overview
Overview. The Winsen ME4-ETO is a constant potential electrolysis gas sensor for ethylene oxide (C2H4O). An oxidation-reduction reaction inside the sensor produces a current proportional to the gas concentration, which is measured to determine the target gas concentration.
Main characteristics. Detection range of 0 to 20 ppm, with a maximum of 100 ppm, resolution of 0.1 ppm and sensitivity of (1.8±0.3) µA/ppm. Response time T90 is below 120 s, output linearity is linear and repeatability is below 2% of the output value. Zero drift is 4 ppm between -20 and 40 ℃, and stability is below 2% per month. Expected service life is 2 years.
Operating conditions. Bias voltage of 300 mV, recommended load resistance of 10 Ω, temperature range of -20 ℃ to 50 ℃, humidity range of 15% to 90% RH without condensation, and standard atmospheric pressure ±10%. Size φ32 × 14.5.
Typical uses. Ethylene oxide detection in petroleum and petrochemical installations, in the pharmaceutical field and for environmental protection. The sensor offers low power consumption, good anti-interference ability, and high repeatability and stability.
Constant potential electrolysis sensor for ethylene oxide (ETO) gas, designed for detection in petroleum and petrochemical, pharmaceutical and environmental protection applications.
Temperature range-20℃~50℃
Pressure rangeStandard atmospheric pressure±10%
Humidity range15%~90% RH (No condensation)
Detection range0-20ppm, Max 100ppm
Max Range100ppm
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
Standard atmospheric pressure±10%
Humidity range
15%~90% RH (No condensation)
Bias voltage
300mV
Characteristics
Detection of ethylene oxide in petroleum and petrochemical, pharmaceutical and environmental protection fields
Detection Gas
Ethylene Oxide (ETO)
Detection Principle
Electrochemical
Detection range
0-20ppm, Max 100ppm
Life span
2 years
Load Resistance
10Ω (recommended)
Max Range
100ppm
Model
ME4-ETO
Output Linearity
Linear
Repeatability
<2% Output value
Resolution
0.1ppm
Response Time (T90)
<120S
Sensitivity
(1.8±0.3) µA/ppm
Size
φ32×14.5
Stability (/month)
<2%
Target
C2H4O
Temperature range
-20℃~50℃
Working Conditions
Resolution ratio 0.1ppm; Response time<120s; Bias voltage 300mV, Anticipated using life 2 years
Zero drift (-20~40℃)
4ppm
Applications and use cases
Architectures in which ME4-ETO can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME4-ETO and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details