MP901 – Semiconductor Air-Quality Gas Sensor, 1-50 ppm Range

Semiconductor Air-Quality Gas Sensor, 1-50 ppm Range

Environmental and Gas Sensors

  • 1-50ppm
  • Semiconductor
  • φ9.4×7.5
  • 5.0V±0.1V DC
Manufacturer part number
MP901
Manufacturer
Winsen
Detection range
1-50ppm
Detection Principle
Semiconductor

Flat surfaced semiconductor sensor for detecting harmful gases in air, including alcohol, smoke, formaldehyde and toluene, over a 1-50 ppm range.

Product overview

Overview. The Winsen MP901 is a flat surfaced semiconductor gas sensor, model MP901, intended for air-quality monitoring. Its conductivity rises with the concentration of the target gas.

Performance. The sensor detects alcohol, smoke, formaldehyde, toluene, acetone, benzene, lighter gas and paint, over a 1-50 ppm range. Its sensor resistance is 95 Ω ±10 Ω under standard test conditions at room temperature.

Power. The standard circuit operates at 5.0 V ±0.1 V DC. The heater voltage is 5 ±0.1 V and heater consumption is 300 mW or less.

Package. The sensor uses a standard metal cap encapsulation, size φ9.4 × 7.5.

Typical uses. It is intended for harmful gas detection in homes and offices, automatic exhaust devices and air cleaners.

See all specifications

Highlights

  • Detection Principle: Semiconductor
  • Detection range: 1-50ppm
  • Model: MP901
  • Sensor Type: Semiconductor flat surfaced sensor
  • Size: φ9.4×7.5
  • Standard circuit: 5.0V±0.1V DC

Typical applications

Derived from the part category, not a compatibility statement.