The Winsen MQ-7B is a semiconductor carbon monoxide sensor covering the 10 to 500 ppm range, in a plastic cap housing measuring φ16.7×9.4.
Detection range10-500ppm
CharacteristicsGood sensitivity to CO
Detection PrincipleSemiconductor
Lifespan10years
ModelMQ-7B
Sensor character under standard test conditions30Ω ±3Ω (room temp.)
Product overview
Overview. The Winsen MQ-7B is a semiconductor carbon monoxide (CO) sensor designed to detect this gas in a range of 10 to 500 ppm. It is supplied in a standard plastic cap housing measuring φ16.7×9.4.
Principle and characteristics. The sensor uses a semiconductor detection principle with good sensitivity to CO. Its sensor resistance is 30 Ω ±3 Ω under standard test conditions (20 ℃ ±2 ℃, 55 % ±5 % RH). Its stated lifespan is 10 years.
Power and operation. Operation relies on a two-level heating cycle: a low temperature heater voltage of 1.5 V ±0.1 V for detection over 90 seconds, followed by a high temperature heater voltage of 5 V ±0.1 V for cleaning over 60 seconds. The loop voltage is 5 V ±0.1 V DC.
Uses. Given its measurement range and defined operating cycle, this sensor suits carbon monoxide detection in monitoring equipment that integrates a controlled heater circuit. Available on quotation from Atlas Electronics.
The Winsen MQ-7B is a semiconductor carbon monoxide sensor covering the 10 to 500 ppm range, in a plastic cap housing measuring φ16.7×9.4.
Detection range10-500ppm
CharacteristicsGood sensitivity to CO
Detection PrincipleSemiconductor
Lifespan10years
ModelMQ-7B
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
Good sensitivity to CO
Detection Principle
Semiconductor
Detection range
10-500ppm
Lifespan
10years
Model
MQ-7B
Notes
Low temperature 90s detection, high temperature 60s cleaning
Sensor character under standard test conditions
30Ω ±3Ω (room temp.)
Sensor Type
Semiconductor
Size
φ16.7×9.4
Standard Circuit; Conditions
5.0V±0.1V DC
Standard Encapsulation
Plastic cap
Standard test conditions
20℃±2℃;55%±5%RH
Target
CO
Target gas
carbon monoxide
Working Conditions
Loop Voltage:5±0.1V; High temp.heater voltage:5±0.1V; Low temp.heater voltage:1.5±0.1V
Applications and use cases
Architectures in which MQ-7B can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details