The RD-624 is a Winsen pyroelectric PIR infrared sensor for human presence detection. Its analog output and dual-element compensation structure suit intrusion detection and presence-controlled lighting.
Current<25uA @Rs=47K
Storage Temperature-40~80º C
Detection Principlepyroelectric effect
Detection rate (D*):1.4 ×108cmHz1/2/W
Infrared receiving electrode2×1mm, 2 sensitive elements
ModelRD-624
Product overview
Overview. The Winsen RD-624 is a pyroelectric passive infrared (PIR) sensor that detects infrared radiation through the pyroelectric effect, that is, through the temperature change caused by the presence of a human body.
Main characteristics. The sensor offers a sensitivity of at least 3200 V/W, an output signal peak of at least 3500 mVp-p, a noise peak below 70 mVp-p and a detection rate D* of 1.4 × 10⁸ cm·Hz^1/2/W. Window transmittance exceeds 75 % and the receiving wavelength range is 5 to 14 µm. Output balance is below 10 %.
Structure and immunity. It uses two complementary sensing elements that compensate interference caused by temperature variations and improve stability. The TO-5 package of 9.1 × 4.5 mm and the 3 × 4 mm window make board-level integration straightforward.
Power and consumption. The working voltage ranges from 3 to 15 V, with a current below 25 µA at Rs = 47K. The source voltage ranges from 0.3 to 1.1 V.
Environment. The sensor operates from -30 °C to 70 °C and can be stored from -40 °C to 80 °C.
Typical uses. Intrusion detection and burglar alarms, indoor access management, human detection lighting, automatic doors and smart home applications.
Integration. The RD-624 provides an analog output that connects directly to the signal processing electronics of the equipment. The manufacturer indicates that this product is discontinued; consulting Winsen's replacement PIR sensors is recommended.
The RD-624 is a Winsen pyroelectric PIR infrared sensor for human presence detection. Its analog output and dual-element compensation structure suit intrusion detection and presence-controlled lighting.
Current<25uA @Rs=47K
Storage Temperature-40~80º C
Detection Principlepyroelectric effect
Detection rate (D*):1.4 ×108cmHz1/2/W
Infrared receiving electrode2×1mm, 2 sensitive elements
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
analog output, high sensitivity, anti-interference, and excellent signal to noise ratio.
Current
<25uA @Rs=47K
Detection Principle
pyroelectric effect
Detection rate (D*):
1.4 ×108cmHz1/2/W
Infrared receiving electrode
2×1mm, 2 sensitive elements
Model
RD-624
Model No.
RD-624
Noise peak[Vp-p]:
<70mV
Notes
This product has been discontinued and find more PIR Sensor
Output balance degree:
<10%
Output signal peak[Vp-p]
≥ 3500mV
Receiving wave length:
5~14µm
Receiving wavelength:
5-14um
Sensitivity
≥ 3200V/W
Size
TO-5 9.1x4.5mm
Source Voltage
0.3~1.1V
Standard Encapsulation
TO-5
Storage Temperature
-40~80º C
Target
human body induction
Transmittance
>75%
Vp-p
<70mV
Window size:
3×4mm
Working Conditions
Working voltage:3-15V
Working temperature
-30~70º C
Working voltage
3~15V
Applications and use cases
Architectures in which RD-624 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for RD-624 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details