The Winsen RPFA913CC is a pyroelectric flame sensor with a 3.8 µm detection band, designed for fire detection. Discontinued according to the manufacturer's data.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
Filter center wavelengthTypical: 3.8; Unit: um
Product overview
Overview. The Winsen RPFA913CC is a pyroelectric flame sensor whose sensitive element is a lithium tantalate single crystal. It detects flame radiation in the 3.8 µm band and provides a voltage output on a single channel.
Main characteristics. TO-5 package, 3 × 3 mm sensitive element, 5.0 × 5.0 mm window. Typical detection distance is above 35 m with a field of view above 115°. Output signal V0 is 2.0 ± 10 % V and output noise voltage is at most 150 mV. Thermal time constant is 200 ms and electrical time constant is 5 s.
Power and environment. Working voltage 2 to 15 V, recommended voltage 3 to 5 V, source voltage 0.4 to 0.7 V. Working and storage temperature -40 to +85 °C.
Typical uses. Flame detection in high fire risk areas such as oil storage stations, warehouses, workshops and forests, according to the manufacturer's documentation.
Integration. Discontinued according to the data provided: the manufacturer refers to the RP911 model. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RPFA913CC, with where it comes from. Use the filters to find one quickly.
All specifications (19)
Characteristic
Value
Characteristics
3.8um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 3.8; Unit: um
Model
RPFA913CC
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 2.0±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RPFA913CC. For a missing document or a specific revision, our experts send it to you.
The Winsen RPFA913CC is a pyroelectric flame sensor with a 3.8 µm detection band, designed for fire detection. Discontinued according to the manufacturer's data.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
3.8um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 3.8; Unit: um
Model
RPFA913CC
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 2.0±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
Applications and use cases
Architectures in which RPFA913CC can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details