Winsen RPFA913CD pyro-electric flame sensor with a 4.3 µm detection band, intended for flame detection in high fire-risk areas. The manufacturer lists this model as discontinued.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
Filter center wavelengthTypical: 4.3; Unit: um
Product overview
Overview. The Winsen RPFA913CD is a pyro-electric flame sensor whose sensitive element is a lithium tantalate single crystal. The data indicate that this product has been discontinued by the manufacturer, which refers to the RP911 model.
Main characteristics. 4.3 µm detection band, TO-5 package, single channel in voltage mode, low microphone effect, large field of view above 115° and high detection rate. The sensitive element measures 3 × 3 mm and the window 5.0 × 5.0 mm. The typical detection distance is greater than 35 m.
Performance. Typical output signal V0 of 4.8 V ±10% (500K, 10 Hz, 25 °C), typical output noise voltage VN at most 150 mV, typical specific detectivity D* of at least 5×10⁸ cmHz½/W, typical voltage response Rv of at least 500 V/W and typical thermal time constant of 200 ms.
Power and environment. Typical working voltage of 2 to 15 V, recommended voltage of 3 to 5 V, source voltage of 0.4 to 0.7 V, and working and storage temperature range of -40 to +85 °C.
Typical uses. Flame detection in high fire-risk areas such as fuel storage stations, warehouses, industrial workshops and charging piles, in line with the applications described by the manufacturer.
Integration. The data do not specify a digital output interface; the signal is provided as an analogue voltage on a TO-5 package.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RPFA913CD, with where it comes from. Use the filters to find one quickly.
All specifications (19)
Characteristic
Value
Characteristics
4.3um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 4.3; Unit: um
Model
RPFA913CD
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 4.8±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RPFA913CD. For a missing document or a specific revision, our experts send it to you.
Winsen RPFA913CD pyro-electric flame sensor with a 4.3 µm detection band, intended for flame detection in high fire-risk areas. The manufacturer lists this model as discontinued.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
4.3um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 4.3; Unit: um
Model
RPFA913CD
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 4.8±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
Applications and use cases
Architectures in which RPFA913CD can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productWinsen
RPFA913CD
Pyro-electric flame sensor with 4.3 µm detection band
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details