Pyro-electric flame sensor with a 4.4 µm detection band in a TO-5 package, for fire detection. The manufacturer lists this product as discontinued and points to RP911 instead.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
Filter center wavelengthTypical: 4.4; Unit: um
Product overview
RPFA913CE flame sensor. The Winsen RPFA913CE pyro-electric flame sensor detects flame signals in the 4.4 µm band. Its lithium tantalate single crystal sensitive element provides good temperature stability.
Main characteristics. Typical detection distance above 35 m, typical field of view above 115°, sensitive element of 3 x 3 mm and window of 5.0 x 5.0 mm. The sensor has a typical thermal time constant of 200 ms and a typical electrical time constant of 5 s. Its typical specific detection rate D* is greater than or equal to 5×10⁸ cmHz½/W.
Signal and power. Typical output signal V0 of 4.5 V ±10%, typical output noise voltage VN less than or equal to 150 mV, typical working voltage of 2 to 15 V and typical recommended voltage of 3 to 5 V. Typical working and storage temperature range of -40 to +85 °C.
Typical uses. Flame monitoring in high fire risk areas such as petroleum, chemical, paper-making, forest and garage environments, as well as in warehouses and factory workshops, according to the applications stated by the manufacturer.
Integration. The sensor is supplied in a TO-5 package, single channel, voltage mode output. The manufacturer lists this product as discontinued and refers to RP911 as the product to consult instead.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RPFA913CE, with where it comes from. Use the filters to find one quickly.
All specifications (19)
Characteristic
Value
Characteristics
4.4um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 4.4; Unit: um
Model
RPFA913CE
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 4.5±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RPFA913CE. For a missing document or a specific revision, our experts send it to you.
Pyro-electric flame sensor with a 4.4 µm detection band in a TO-5 package, for fire detection. The manufacturer lists this product as discontinued and points to RP911 instead.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
4.4um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 4.4; Unit: um
Model
RPFA913CE
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 4.5±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
Applications and use cases
Architectures in which RPFA913CE can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details