Winsen RPFA913CG pyroelectric flame sensor with voltage output for flame detection in high fire-risk areas. The manufacturer lists this product as discontinued.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
Filter center wavelengthTypical: 5.0; Unit: um
Product overview
RPFA913CG flame sensor. The Winsen RPFA913CG is a pyroelectric flame sensor using a monocrystalline lithium tantalate sensitive element, in a single-channel TO-5 package with voltage-mode output. Main characteristics — 5.0 µm detection band, typical field of view above 115°, typical detection distance above 35 m, typical specific detectivity D* of at least 5×10⁸ cmHz½/W and typical thermal time constant of 200 ms. The manufacturer states low microphone effect and a high detection rate. Power and environment — Typical working voltage of 2 to 15 V, recommended voltage of 3 to 5 V, working and storage temperature of -40 to +85 °C. Typical uses — The manufacturer cites oil storage stations, large warehouses, factory workshops, forests, charging piles and high fire-risk areas such as petroleum, chemical, paper-making and garages. Note — This product is listed by the manufacturer as discontinued, with the RP911 indicated as the reference to find. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RPFA913CG, with where it comes from. Use the filters to find one quickly.
All specifications (19)
Characteristic
Value
Characteristics
5.0um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 5.0; Unit: um
Model
RPFA913CG
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 4.3±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RPFA913CG. For a missing document or a specific revision, our experts send it to you.
Winsen RPFA913CG pyroelectric flame sensor with voltage output for flame detection in high fire-risk areas. The manufacturer lists this product as discontinued.
Working temperature/ Storage temperatureTypical: -40~+85; Unit: ℃
Detection DistanceTypical: >35; Unit: m
Detection Principlepyroelectric effect
Electrical time constantTypical: 5; Unit: s
Field of View (FOV)Typical: >115; Unit: °
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
5.0um detection band; TO-5 package, single channel, voltage mode; Low microphone effect, large FOV, high detection rate; Detection band measurement of flame signal
Detection Distance
Typical: >35; Unit: m
Detection Principle
pyroelectric effect
Electrical time constant
Typical: 5; Unit: s
Field of View (FOV)
Typical: >115; Unit: °
Filter center wavelength
Typical: 5.0; Unit: um
Model
RPFA913CG
Notes
This product has been discontinued and find more RP911
Output noise voltage VN (10HZ, BW1HZ, 25℃)
Typical: ≤ 150; Unit: mv
Output signal V0 (500K,10HZ,25℃)
Typical: 4.3±10%; Unit: v
Recommended Voltage
Typical: 3~5; Unit: v
Sensitive element size
Typical: 3*3; Unit: mm
Source Voltage
Typical: 0.4~0.7; Unit: v
Specific detection rate (no window) D* (500K, 10HZ, BW1HZ, 25℃)
Typical: ≥ 5×108; Unit: cmHz½ /W
Thermal time constant
Typical: 200; Unit: ms
Voltage response rate (no window) Rv (500K, 10HZ, 25°C)
Typical: ≥ 500; Unit: v/w
Window size:
Typical: 5.0*5.0; Unit: mm
Working temperature/ Storage temperature
Typical: -40~+85; Unit: ℃
Working voltage
Typical: 2~15; Unit: v
Applications and use cases
Architectures in which RPFA913CG can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.