Winsen ZEHS04 atmospheric monitoring module detecting CO, SO2, NO2 and O3 with electrochemical cells, offering UART and RS485 outputs for air quality monitoring.
Detection rangeSee manual
Power consumption≤ 1W
Storage Temperature-20~50℃
Response time≤ 120S
Detection PrincipleModule, electrochemical
Life span2 years (based on sensor life span)
Product overview
Winsen ZEHS04. The Winsen ZEHS04 atmospheric monitoring sensor module is a diffusion-type multi-in-one module detecting CO, SO2, NO2 and O3 in a single housing. It can be externally connected to a dust sensor module and a temperature and humidity sensor module for PM2.5, PM10, temperature and humidity measurement.
Main characteristics. The module offers a resolution of 10 ppb or less, a response time and a resume time of 120 s or less, a power consumption of 1 W or less and a working life of 2 years, according to the sensor life. Its dimensions are 12 cm × 10 cm × 6 cm (L × W × H).
Interfaces and connectivity. The module provides a UART output (3 V TTL, 5 V compatible) and an RS485 output, which simplifies integration and debugging during development.
Power and environment. It operates from a DC supply of 9 to 24 V, at a working temperature of -20 to 50 °C and a working humidity of 15 to 90 % RH without condensation. Its storage temperature ranges from -20 to 50 °C.
Typical uses. Urban atmospheric environmental monitoring, monitoring of unorganized pollution emissions at factory sites, portable instruments, air quality monitoring equipment and smart home equipment.
Integration. The module is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for ZEHS04, with where it comes from. Use the filters to find one quickly.
All specifications (18)
Characteristic
Value
Response time
≤ 120S
Characteristics
Urban atmospheric environmental monitoring; Unorganized emissions of pollution monitoring at factory sites; Portable instruments, air quality monitoring equipment, and smart home equipment.
Winsen ZEHS04 atmospheric monitoring module detecting CO, SO2, NO2 and O3 with electrochemical cells, offering UART and RS485 outputs for air quality monitoring.
Detection rangeSee manual
Power consumption≤ 1W
Storage Temperature-20~50℃
Response time≤ 120S
Detection PrincipleModule, electrochemical
2. Datasheet extract (recorded values)
Parameter
Value
Response time
≤ 120S
Characteristics
Urban atmospheric environmental monitoring; Unorganized emissions of pollution monitoring at factory sites; Portable instruments, air quality monitoring equipment, and smart home equipment.
CO, SO2, NO2, O3 (PM2.5, PM10, temperature and humidity expansion compatible)
Working Conditions
Resolution 1ug/m3; Response time ≤ 120S; Working life 2 years (According to sensor's Working life)
Working humidity
15~90% RH (no condensation)
Working temperature
-20~50℃
Working voltage
DC 9~24V
Applications and use cases
Architectures in which ZEHS04 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productWinsen