Natural gas leakage detection module with a semiconductor sensor, designed for vehicle-mounted fuel gas leak alarms, with one signal output.
Detection range1~ 25%LEL
Working current<80mA
Storage EnvironmentTemp.:-20~105℃
AccuracyAt normal temp. ±3%LEL
Response time< 30s
Detection GasNatural Gas
Product overview
Overview. The Winsen ZP06 is a semiconductor gas leakage detection module designed for vehicle-mounted fuel gas leak alarms. It detects natural gas over a range of 1 to 25%LEL.
Main characteristics. The flat surfaced semiconductor sensor offers ±3%LEL accuracy at normal temperature, with a response time under 30s and a resume time under 30s. Its expected life is over 2 years. The stated characteristics include high sensitivity, wide voltage input, strong anti-jamming capability, good stability and shock resistance.
Interfaces and output. The module provides one signal output, labelled S.
Power and environment. It operates on DC 9~32V with a working current under 80mA. The working temperature range is -40 to 85℃ and the storage temperature range is -20 to 105℃.
Dimensions. The module measures 33mm in diameter and 17.5mm in height.
Typical uses. This module integrates into a vehicle-mounted natural gas leak alarm, using the signal output and power supply listed above.
Natural gas leakage detection module with a semiconductor sensor, designed for vehicle-mounted fuel gas leak alarms, with one signal output.
Detection range1~ 25%LEL
Working current<80mA
Storage EnvironmentTemp.:-20~105℃
AccuracyAt normal temp. ±3%LEL
Response time< 30s
2. Datasheet extract (recorded values)
Parameter
Value
Response time
< 30s
Accuracy
At normal temp. ±3%LEL
Characteristics
High sensitivity, wide voltage input, strong anti-jamming capability, good stability and shock resistance
Detection Gas
Natural Gas
Detection Principle
Semiconductor
Detection range
1~ 25%LEL
Expected Life
>2 years
Model
ZP06
Output
1Signal output S
Resume Time
< 30s
Sensor Type
Flat surfaced semiconductor
Size
Diameter33mm*17.5mm
Storage Environment
Temp.:-20~105℃
Target
Natural Gas
Working current
<80mA
Working Environment
Temp.:-40~85℃
Working voltage
DC 9~32V
Applications and use cases
Architectures in which ZP06 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ZP06 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productWinsen
ZP06
Vehicle-Mounted Natural Gas Leakage Detection Module
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details